en | 4-Reader Boards and 8 Input/8 Output Boards
Connector T2 (top connector)
Pin#
1
2
3
4
5
6
Connector T3 (second connector from top)
Pin#
1
2
3
4
5
6
Connector T4 (third connector from top)
Pin#
1
2
3
4
5
6
Connector T5 (bottom connector)
Pin#
1
2
3
4
5
6
NOTICE!
i
The common alarm output relay only exists on 4-reader board 1. On cards 2, 3 and 4 this relay
is an additional spare.
Ver 2.0.0 | 2006.07
Function
Reader #1 (common)
Reader #2 (Normally closed)
Reader #1 (normally open)
Reader #2 (common)
Reader #2 (normally closed)
Reader #2 (normally open)
Function
Reader #3 (common)
Reader #3 (Normally closed)
Reader #3 (normally open)
Reader #4 (common)
Reader #4 (normally closed)
Reader #4 (normally open)
Function
Spare (common)
Spare (Normally closed)
Spare (normally open)
Spare (common)
Spare (normally closed)
Spare (normally open)
Function
Spare (common)
Spare (Normally closed)
Spare (normally open)
Common Alarm Output (common)
Common Alarm Output (normally
closed)
Common Alarm Output (normally
open)