Parameters For The Sms Function; Parameters For The Ssm Function - ABB ACS880 Series Manual

Safely-limited speed with the encoder interface (option +q965)
Hide thumbs Also See for ACS880 Series:
Table of Contents

Advertisement

46 Parameter settings
Index
Name
I/O settings
SAFEIO.36
DI X113:4 diag pulse
on/ off
SAFEIO.40
DI X114:4 diag pulse
on/ off
SAFEIO.57
DO X114:8 diag
pulse on/off
SAFEIO.75
DO X114:8 logic
state

Parameters for the SMS function

These parameters are related to the SMS function (version 1) of the FSO module.
Index
Name
200.71
SMS activity and ver-
sion
SMS.13
SMS trip limit negat-
ive
SMS.14
SMS trip limit positive

Parameters for the SSM function

There are four separate SSM functions (SSM1...4) in the FSO module. The SSM functions
are identical and the configuration is done similarly, only the parameter numbers differ. The
Example value
Description
On
Sets the diagnostic pulse of digital input
X113:4 on or off.
On: The input monitors that it receives test
pulses.
On
Sets the diagnostic pulse of digital input
X114:4 on or off.
On: The input monitors that it receives test
pulses.
On
Sets the diagnostic pulse of digital output
X114:8 on or off.
On: The output monitors that it receives test
pulses.
Active high
Sets the logic state of digital output X114:8.
Active high: The digital output is on when
the indicated signal is active.
For option +Q965, ABB has configured the
SLS indication signal to this digital output at
the factory. Make sure that this value corres-
ponds to the actual wiring. See the circuit
diagrams of the delivery.
Example value
Description
Version 1
Activates or deactivates the SMS function
and shows the version of the SMS function.
Disabled: Deactivates the SMS function
(default).
Version 1: Activates version 1 of the SMS
function.
Version 2: Activates version 2 of the SMS
function (for more information, see the FSO
module user's manual).
For option +Q965, ABB has configured the
SMS function (Version 1) at the factory.
Adjust the value if necessary.
-2000 rpm
Sets the negative speed limit that trips the
drive for the SMS function.
Note: You cannot set this limit above the
general zero speed limit (parameter FSO-
GEN.52).
2000 rpm
Sets the positive speed limit that trips the
drive for the SMS function.
Note: You cannot set this limit below the
general zero speed limit (parameter FSO-
GEN.52).

Advertisement