Non-Authorised Code Evaluation; Programming; Door Release Time; Programming Mode - Honeywell 025050 Mounting And Operating Manual

Compact door code unit
Table of Contents

Advertisement

Available languages

Available languages

Mounting and Operating Manual
3.

Non-authorised code evaluation

It is practically impossible to discover a valid code through trial and error.
The complete digit combination of a valid code must be input after a certain number of keys are
actuated. The keypad input is blocked for 30 seconds if this is not the case. This status is not
noticeable from outside.
The number of erroneous inputs permitted until the keyboard is blocked depends on the program-
med codes. It is equivalent to double the number of digits of the longest programmed code.
For example, a valid code must be input in full length after the twelfth key actuation at the latest
during an inputting attempt if a main code with six digits is programmed. T
seconds if this is not the case
4.

Programming

4.1

Door release time

The door release time can be set to a value between one and thirty seconds with the rotary
knob (see illustration below). The time is adjusted in 2-second steps. The release duration is
one second at switch position "0".
4.2

Programming mode

It is necessary to switch to programming mode
in order to program codes via the unit keypad. A
key is required for this to open the unit.
Switching to programming mode is realised by
briefly pressing the programming key (see
illustration).
It can be identified by the
on the front of the unit.
The unit is automatically reset to normal
operating mode if no keys are actuated within
15 seconds of activating programming mode.
4.3

Main code programming

Example: The digit sequence 659874 is to be programmed as the main code.
Note:
An existing code is written over.
6 5 9 8 7 4
Compact Door Code Unit
.
flashing green LED
Open the unit with the key
Activate programming mode by actuating the programming key
Input the (new) main code on the unit keypad. The code is
imported, as the maximum digit number (6) is achieved, and the
unit is reset automatically to normal operating mode.
he keypad is blocked for 30
Marked position: 0
ON
1 2 3 4 5 6 7 8
Programming key
Rotary knob for
door release time
15
0=1 sec
1=2 sec
2=4 sec
3=6 sec
F=30 sec
All switches in
OFF
position
OFF
Main PCB

Advertisement

Chapters

Table of Contents
loading

Table of Contents