Honeywell Domonial CMI 800++ Installer Manual page 10

Table of Contents

Advertisement

Available languages

Available languages

EKZ000300C
TECHNICAL APPENDIXES
5 -
5-1 Radio Jamming diagram
The default appears if the jamming level in one of the channels is lower from one unit for 30 seconds than the level of the peripheral
with the worse level, in 60 seconds time slot. After that, and for one hour, the jamming detection is disabled (only in the log = no
transmission).
Peripheral 1 : level 10
10
Peripheral 2 : level 8
9
8
7
Peripheral 3 : level 4
6
5
4
3
2
1
0
60 second time slot
30 second time slot (added up)
The default disappears if the jamming level is lower for 20 consecutive seconds than the worse radio level receive from the peripherals
and for all channels.
Peripheral 1 : level 10
Peripheral 2 : level 8
Jamming level can be checked using the programming tool on the diagnosis section.
Installer instructions / Manuel installateur - Domonial CMI 800++ 11/2005
-1
- Transmission of « jamming » default if programmed
- Technical beeps if programmed
- Siren if « total » arming only (depending on version)
- Log file
- Launching one hour time slot for « jamming » disabling
One hour time slot
20 second time slot
time
time
- End of « jamming » default transmission
- Log file
Lowest peripheral radio level (RLmini)
Jamming fault trigger level,
(= receiving level RLmini - 1)
Jamming level
Radio jamming level
Jamming level
Page : 10/24