Rf Test Mode; Figure 4-2. Side Button Locations; Table 4-1. Initial Equipment Control Settings - Motorola Commercial Series Basic Service Manual

Hide thumbs Also See for Commercial Series:
Table of Contents

Advertisement

4-2
Initial equipment control settings should be as indicated in
performance checks and tuner alignment procedures.
Monitor Mode: Power Monitor
RF Attenuation: -70
AM, CW, FM: FM
Oscilloscope Source: Mod
Oscilloscope Horiz: 1 0 mSec/Div
Oscilloscope Vert: 2.5kHz/Div
Oscilloscope Trig: Auto
Monitor Image: Hi
Monitor BW: Nar
Monitor Squelch: mid CW
Monitor Vol: 1/4 CW
4.3

RF Test Mode

When the radio is operating in its normal environment, the radio's microcomputer controls the RF
channel selection, transmitter key-up, and receiver muting, according to the customer codeplug
configuration. However, when the unit is on the bench for testing, alignment, or repair, it must be
removed from its normal environment using a special routine, called RF TEST MODE. This mode
allows bench testing of the radio at various test frequencies across the entire band, at both high and
low transmit power (if applicable), at various channel spacings, and with different coded or carrier
squelch types. Any customer specific programming in the radio will not be changed or affected by use
of the RF Test Mode..
Note: Radio Setup Requirement
Ensure at least one Conventional Personality Channel is programmed on the radio for RF
Test Mode to function properly.
October, 2009

Table 4-1. Initial Equipment Control Settings

Service Monitor
Side Button 1
Side Button 2

Figure 4-2. Side Button Locations

Performance Checks: RF Test Mode
Table 4-1
and should be the same for all
Test Set
Power Supply
Spkr set: A
Voltage: 7.5 Vdc
Spkr/load:
DC on/standby:
Speaker
Standby
PTT: OFF
Volt Range: 10 V
Current: 2.5 A
68009328001-A