Midi Out - Yamaha MOTIF ES6 Data List

Music production synthesizer
Hide thumbs Also See for MOTIF ES6:
Table of Contents

Advertisement

(3-3) REGISTERED PARAMETER NUMBER
STATUS
1011nnnn(BnH)
LSB
01100100(64H)
RPN LSB
0ppppppp
MSB
01100101(65H)
RPN MSB
0qqqqqqq
DATA ENTRY MSB
00000110(06H)
DATA VALUE
0mmmmmmm
DATA ENTRY LSB
00100110(26H)
DATA VALUE
0lllllll
First, designate the parameter using RPN MSB/LSB numbers. Then, set its value with data entry MSB/LSB.
RPN
D.ENTRY
LSB MSB
MSB LSB
PARAMETER NAME
00H 00H
mmH ---
PITCH BEND SENSITIVITY
01H 00H
mmH llH
MASTER FINE TUNE
{mmH,llH}={00H,00H}-{40H,00H}-{7FH,7FH}
(-8192*100/8192) - 0 - (+8192*100/8192)
02H 00H
mmH ---
MASTER COARSE TUNE
28H - 40H - 58H (-24 - 0 - +24 semitones)
7FH 7FH
--- ---
RPN RESET
RPN numbers will be left not designated.
The internal values are not affected.
(3-4) NON-REGISTERED PARAMETER NUMBER
There are no applicable parameters.
These are transmitted to the Plug-in board.
(3-5) SYSTEM REAL TIME MESSAGES
STATUS
11111110(FEH)
Transmitted at every 200 msec.
Once this code is received, the instrument starts sensing. When no status nor data is received for over
approximately 350 ms, MIDI receiving buffer will be cleared, and the sounds currently played is forcibly turned off.
(3-6) SYSTEM EXCLUSIVE MESSAGE
F0H 7EH 7FH 09H 01H F7H
The PLG100-XG Plug-in board installed to the instrument, will receive this message when the instrument is in the
Song/Pattern mode and SYSTEM Receive GM/XG is set to on. The Part values will be reset according to the
SYSTEM Internal Part settings.
The internal tone generator block will receive this message when the instrument is in the Song/Pattern mode.
F0H 7EH 0nH 06H 01H F7H
("n" = Device No. However, this instrument receives under "omni.")
F0H 7EH 7FH 06H 02H 43H 00H 41H ddH ddH 00H 00H 00H 7FH F7H
dd; Device Number Code
MOTIF ES6: 69 05
MOTIF ES7: 6A 05
MOTIF ES8: 6B 05
F0H 7FH 7FH 04H 01H llH mmH F7H
Sets the MASTER VOLUME value.
The value "mm" is used to set the master volume (the value "ll" should be ignored).
11110000
F0
01000011
43
0001nnnn
1n
01001100
4C
0aaaaaaa
0
0aaaaaaa
0
0aaaaaaa
7E
0
0
11110111
F7
The PLG100-XG Plug-in board installed to the instrument, will receive this message when the instrument is in the
Song/Pattern mode and SYSTEM Receive GM/XG is set to on. The Part values will be reset according to the
SYSTEM Internal Part settings.
The internal tone generator block will not receive this message.
Be aware that executing this message takes about 170 ms, and that an appropriate interval must be allowed before
executing the subsequent message.
11110000
F0
01000011
43
0001nnnn
1n
01111111
7F
00000000
00
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
0ddddddd
ddddddd
|
|
11110111
F7
For parameters with data size of 2 or more, the appropriate number of data bytes will be transmitted.
See the following MIDI Data Table for Address and Byte Count.
66
Data List
n = 0 – 15 CHANNEL NUMBER
p = RPN LSB
(Refer to the table as shown below.)
q = RPN MSB
(Refer to the table as shown below.)
m = Data Value
l = Data Value
DATA RANGE
00H - 18H (0 - 24 semitones)
Exclusive Status
YAMAHA ID
Device Number
Model ID
Address High
Address Mid
Address Low
Data
End of Exclusive
Exclusive Status
YAMAHA ID
Device Number
Model ID
Model ID
Address High
Address Mid
Address Low
Data
End of Exclusive
11110000
F0
01000011
43
0000nnnn
0n
01111111
7F
00000000
00
0bbbbbbb
bbbbbbb
0bbbbbbb
bbbbbbb
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
0
0
|
|
0ccccccc
ccccccc
11110111
F7
See the following BULK DUMP Table for Address and Byte Count.
The Check sum is the value that results in a value of 0 for the lower 7 bits when the Byte Count, Start Address, Data
and Check sum itself are added.
11110000
F0
01000011
43
0010nnnn
2n
01111111
7F
00000000
00
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
11110111
F7
See the following DUMP REQUEST Table for Address and Byte Count.
11110000
F0
01000011
43
0011nnnn
3n
01111111
7F
00000000
00
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
11110111
F7
See the following MIDI Data Table for Address.
(4) SYSTEM OVERVIEW
(Keyboard, Sequencer and Tone Generator)
MIDI IN/OUT = MIDI
SEQ
KBD
Local Sw
TG
MIDI IN/OUT = USB or mLAN
SEQ
KBD
Local Sw
TG
Although three types of note on/note off data, received via MIDI, played by the internal sequencer and played on the
keyboard will be distinguished, the other controllers (channel messages) equally affect the entire notes.
ALL SOUND OFF clears all the sounds in the specific channel(s) played by both the keyboard and the data via MIDI.
ALL NOTES OFF received via MIDI clears the sounds in the specific channel(s) played via MIDI.
Exclusive Status
YAMAHA ID
Device Number
Model ID
Model ID
Byte Count
Byte Count
Address High
Address Mid
Address Low
Data
Check-sum
End of Exclusive
Exclusive Status
YAMAHA ID
Device Number
Model ID
Model ID
Address High
Address Mid
Address Low
End of Exclusive
Exclusive Status
YAMAHA ID
Device Number
Model ID
Model ID
Address High
Address Mid
Address Low
End of Exclusive
To USB/mLAN
From USB/mLAN

MIDI Out

MIDI In
To USB/mLAN
From USB/mLAN
Thru Port
MIDI Out
MIDI In

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Motif es7Motify es8Motif es8

Table of Contents