Operations

The unit's settings can be configured remotely via the
network or manually via the unit's DIP switches.
Remote settings configuration requires a server
computer connected to the network and the Network
System Manager software (not supplied). For details,
refer to the instructions for use for the Network System
Manager software.
This section describes manual settings configuration via
the unit's DIP switches.

Manual Configuration

Before operating the unit, configure settings according
to the connection environment.
If changes are made to the connection environment,
reconfigure settings according to the new environment.
Configuration flow

Removing the DIP Switch Cover

Operation Mode Settings

Video Format Settings

Downconvert Output Settings
Network Settings
Video transmission groups
Receiver IP address
Compression Mode Settings
Network Redundancy Settings
3D Video Settings
Attaching the DIP Switch Cover
Notes
Disconnect the DC power cable before configuring
settings.
Changes to settings will be applied the next time the
unit turns on.
Removing the DIP Switch Cover
Loosen the screw securing the DIP switch cover at the
rear of the unit, and remove the DIP switch cover.
DIP switches 1 to 3 will be revealed.
Operation Mode Settings
Configure this according to the unit's operation mode.
Operation mode
Receiver mode (connected to
monitor)
Sender mode (connected to
video output device)
Video Format Settings
Configure the video format according to the input video
format from the connected modality device.
17
Screw
DIP switches
DIP switch 1 DIP switch 2
[1]
[1]
OFF
ON
ON

Advertisement