Signaling - ABB HF Series Manual

Electronic compact starter
Table of Contents

Advertisement

29
E L E C T R O N I C C O M PA C T S TA R T E R | M A N U A L
4.4

Signaling

The electronic compact starter provides visual confirmation of the operating status with four LEDs. The functions of the
LEDs follow NAMUR NE 44 recommendations.
LED
PWR
ERR
Iadj / L
ON / R
After the control supply voltage U
Signaling for DOL-types
The following table shows the LED codes for
• HF0.6-DOL-24VDC
• HF2.4-DOL-24VDC
• HF9-DOL-24VDC
Operation Status
The electronic compact starter uses the LEDs to indicate the status messages for operation, fault and test:
Status
Description
LED colors on HMI (human machine interface)
OFF
Supply voltage not present
Ready to operate
Supply voltage present
Drive switched on
Forward running motor
Internal error
Internal device error –
device replacement required
External error in the
Motor protection function: The motor current is higher than
controller or I/O
the nominal motor current specification (e.g. Class 10A):
devices (maintenance
Cooling time is running (20 min.)
requirement)
After two min., 'ON' flashes: a manual reset is possible
Error restoring the system state: Checksum error. The
thermal memory of the motor protection function is set to
the maximum value. The error must be manually
acknowledged.
Symmetry: The two motor currents deviate from each other
by more than 33%.
Blocking: The max. measurable motor current is exceeded
for more than two sec..
Message (power path
Message with pending control signal:
remains switched on)
- Two or more phases are missing
- No motor connected
- Motor current in at least two phases > two sec. minimum
current value that can be set
Table 10 Signaling DOL-types
1) Bridge between the terminals 'RES' and 'AUT';
2) No other measures necessary
Green
Red
Yellow
Yellow
is applied, all LEDs light up once for 0.5 sec., as an LED test.
s
Meaning
General device status
Indicates a message
Internal or external error
Device is active
Device is active
PWR
ERR
I
adj.
Green
Red
Yellow
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
Flashes
OFF
ON
Flashes
OFF
ON
Flashes
Flashes
ON
Flashes
OFF
ON
Flashes
OFF
Flashes
Flashes
OFF
ON
Error acknow-
ledgment
OFF
-
OFF
-
ON
OFF
Not possible
ON
Automatic
1)
Flashes
Manual
Flashes
Manual
OFF
Manual
Flashes
Manual
ON
Automatic
2)

Hide quick links: