Shared Commissioning Of Projects - Siemens SIMATIC S7-1500 System Manual

Drive controller
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

Result
The "Get_IM_Data" instruction has stored the I&M0 data in the data block.
You can view the I&M0 data online in STEP 7, for example, in the data block with the
"Monitor all" button. The CPU in the example is a CPU 1507D TF (6ES7615-7DF10-0AB0)
with the firmware version V2.8.
Figure 11-6
11.11

Shared commissioning of projects

Team Engineering
In Team Engineering, several users from various engineering systems work on a project at
the same time and access one SIMATIC Drive Controller CPU.
The users can edit separate parts of a master project independently of one another at the
same time. When the configuration is loaded to the CPU, the CPU shows changes by the
other editors in a synchronization dialog and – if possible – synchronizes the changes
automatically.
Certain online functions can also be executed in parallel from several engineering systems
on a shared CPU, for example:
● Monitoring blocks on the CPU
● Modifying blocks on the CPU
● Trace functions
You can find detailed information on the topic of Team Engineering in the STEP 7 online
help.
SIMATIC Drive Controller
System Manual, 11/2019, A5E46600094-AA
Example: I&M0 data of an S7-1500 CPU
11.11 Shared commissioning of projects
Commissioning
227