  • Page 1 CGLine+ Web Controller Installation and Operating Instructions CGLine+ Web-Controller Target group: Electrical specialists...
  • Page 2: Table Of Contents

    7 .24 Overview all Web-Controller ............. . 27 Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 3: Introduction / Foreword

    CGVision software: Network PC or CGLine+ Wireless analysis at the PC Configuration and full visualisa- Monitoring Set (optional): Access tion of 32 x 800 luminaires to the integrated web interface Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 4: Safety Notes

    (e.g., minimum 10 characters, mix of upper- and lower-case and special characters, and expire every 90 days, or oth- erwise in accordance with your organization’s policies). Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 5: Technical Data

    Flash yellow and green during data transmission. Solid green when connected but no traffic in prog- ress. LED display on the LAN (ethernet connection): Green = flashes with traffic Yellow = link or network connection Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 6: Push Button Functions

    S1/S2 = Block input USB2 device for connection to PC In1, In2 = 2 x digital inputs PE/N/L 230V 50/60Hz 11, 12, 14, 21, 22, 24 = 2 x relay outputs Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 7: Connections

    Polarity D1/D2 to the luminaires must not be observed. Cable routing for CGLine bus: 2-core bus line, unshielded, free bus topology possible. CGLine 1 kOhm Interface Resistor must be connected next to the switch. Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 8: First Commissioning And Modifying

    This USB connection enables connection of the CGLine+ Web-Controller to a standard PC. Controller functions can be programmed via the PC and a configuration software, e.g. luminaire configurations. The PC configuration soft- ware is available optionally. Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 9 192.168.1.50. Subnet mask: 255.255.255.0. Clicking on OK assumes the settings so that the web page of the CGLine+ Web-Controller can now be opened via any web browser, e.g. Firefox. Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 10: First Access To The Cgline+ Webserver

    Before accessing the web server, two security pages are displayed on the browser by security protocols. The following web pages appear: Click on Continue to this website on the first page. Click on Advanced on the second page, and then on Add Exception. Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 11: Login To The Cgline+ Webserver

    6.4 Login to the CGLine+ webserver To setup the networks settings to the IT pretendings, it is necessary to log in as „Admin“ with factory default password “EATON” , see above. After loggin in, the following screen appears: The submenus appear. In the submenu „configura-...
  • Page 12: Modifying Of The Network Settings

    The CGLine+ Web- Controller can now be integrated in the custom- er’s intranet. The access from any PC workstation in the intranet via a stan- dard webbrowser is pos- sible now. Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 13: Common Operation Of The Web Screens

    It is recommended to share the password only to people that need it, and to restrict the use of the Admin pass- word. Periodic update of passwords is also recommended for security reasons. Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 14: Start Screen After Registration

    Logbook: Displays the last 100 events of the inspection book on the SD card Building layouts: Displays luminaires in layouts for each zone Overview all Web-Controllers: Displays further installed CGLine+ Web-Controllers in an overview Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 15: Overview Of All Faulty Luminaires (Complete Overview)

    • Battery = battery or charge error • Luminaire position = target designation • White clock = FT failure of luminaire • Blue clock = DT failure • i = luminaire operation mode Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 16: Overview Of All Faulty Luminaires For Each Zone

    “Overview” menu and the “Zone” tab Via the drop down menus the desired line and zone are selected. The luminaire list is updat- ed via „Send“ Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 17: Overview Of All Luminaires

    200 characters (e.g. destination text) of each luminaire. These text can be edited CGLine+ PC software CGVision With click on the text on this screen Import of an text-file (see Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 18: Configuration Change Of Luminaires Addresses

    2. Click on the line you want to modify and choose the new configurations. 3. Click on Save for taking into account the changes. 4. Click on Validate for finalizing the modifications. Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 19: Switching Command Screen

    Update luminaire status: Actualisiation of the lumi- If “All” is selected: Command applies to all lumi- naire status of all luminaires naires Update luminaire type: Actualisation of luminaire type information Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 20: Device Information Screen

    If the period of mains failure is greater than 21 days, the complete system should be re-commissioned. Especially the date and time must be reconfigured to assure proper sequencing of the test. Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 21: Digital Input/Output" Configuration Screen

    Charging failure: At least 1 luminaire has a battery or charge fault Test failure: At least 1 luminaire has an FT or DT fault, e.g. nominal operating time not reached Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 22: General Device Settings

    IT-department, factory default is 192.168.1.200 Subnet mask: Normally provide by the IT-department, factory default is 255.255.255.0 (Class C) Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 23: Configuration Of E-Mail

    June 2014. A complete logbook is downloadable via log- book.dat. This file is only usable with the CGLine+ PC-software! (see manual CGLine+ PC-software) Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 24: Last Events

    External programs are required, which are described in the manual for the building layout programming (available on request). Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 25: Building Layout - Add A Layout

    = normal opera- tion yellow = FT or DT active red = failure Via menu “Building lay- outs” it is possible to go back to the building layout menu. Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 26: Layout Programming - Searching For A Device

    7.22 Layout programming – deleting a layout In the menu “Delete layout” any graphics created can be deleted again from the web server. Selected plans are removed again via “Delete layout” . Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 27: Multi-Site Configuration

    Status display of zones, inputs and outputs of all CGLine+ web controllers installed in the network. CGLine+ web control- lers installed in the net- work Installation and Operating Instructions CGLine+ Web-Controller 40071860236 (E) February 2019 www.eaton.com...
  • Page 28 Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it’s needed most. With unparalleled knowledge of electrical power management across industries, experts at Eaton deliver customized, integrated solutions to solve our customers’ most critical challenges.