6. troubleshooting

Problem
Cause
The water does not
There is no power.
heat up and the ON/
OFF indicator does
not illuminate.
The water does not
The temperature is set
heat up sufficiently
too low.
and the ON/OFF indi-
cator illuminates.
The appliance heats,
for example, after
large amounts of
DHW have been
drawn.
The flow rate is low.
The aerator in the
tap or shower head is
scaled up or contam-
inated.
If you cannot remedy the fault, notify your qualified con-
tractor. To facilitate and speed up your enquiry, please
provide the numbers from the type plate (000000 and
0000-000000):
16
Remedy
Check the fuses/
MCBs in your fuse
box.
Select a higher tem-
perature.
Wait until the ON/OFF
indicator goes out.
Clean and/or descale
the aerator or shower
head.
E-NO.: 000000
F-NO.: 0000-000000
instAllAtion

7. Safety

Only a qualified contractor should carry out installation,
commissioning, maintenance and repair of the appliance.
7.1
General safety instructions
We guarantee trouble-free function and operational relia-
bility only if original accessories and spare parts intended
for the appliance are used.
7.2
Instructions, standards and regulations
note
Observe all applicable national and regional regula-
tions and instructions.

8. Appliance description

8.1
Standard delivery
The following are delivered with the appliance:
◦ Safety valve
The safety valve supplied must not be used in
Belgium. For use here please use standard safety
valves (see also pricelist).
◦ Temperature indicator
8.2 Accessories
Pressure-tested taps are available as accessories.

9. Preparations

9.1
Installation site
The appliance is designed to be permanently wall-mount-
ed to a solid surface. Ensure the wall offers adequate load
bearing capacity.
There should be a suitable drain near the appliance to
drain off the expansion water.
Always install the appliance vertically in a room free from
the risk of frost and near the draw-off point.
It may not be fitted in a corner since the screws for fixing
the appliance to the wall must remain accessible.