FIG.19
/
STATUS LIGHTS
@
MAIN POWER
r_
CALL FOR HEAT
C[RCUL_TOR PUMP
@
GAS VALVE
BURNER
SYSTEM
STATUS
LIGHT
STATUS
INDICATES
ON
L7148F CONTROL
ENERGIZED
THROUGH
24 VOLT TRANSFORMER.
POWER
OFF
L7148F CONTROL
NOT ENERGIZED.
CALL FOR HEAT/
ON
L7148F CONTROL
ENERGIZING
CIRCULATOR
PUMP CIRCUIT.
CIRCULATOR
PUMP
OFF
CIRCULATOR
PUMP IS NOT ENERGIZED.
ON
L7148F CONTROL
ENERGIZING
GAS CONTROL
VALVE (GAS VALVE OPEN)
GAS VALVE / BURNER
OFF
GAS VALVE NOT ENERGIZED
(GAS VALVE CLOSED)
L7148F
CONTROL
LED ERROR
CODES
LIGHT
STATUS
INDICATES
ON
L7148F CONTROL
ENERGIZED
FULLY FUNCTIONAL.
OFF
L714BE CONTROL
NOT ENERGIZED.
L7148F
LED STATUS
(2) BLINKS
SENSOR ERROR (SHORTED
OR OPEN SENSOR).
LIGHT
(3) BLINKS
ANOLOG TO DIGITAL
ERRORS (SET-POINT
POT FAILURE).
(4) BLINKS
RELAY FAILURE
(CONTROL
FAILURE)
25