3.4.2 Alarm and Status Monitoring of IDU and ODU

3-50
Alarm conditions are identified by the IDU indicator on the IDU. Also the
working conditions of the IDU and ODU can be monitored by the PC, as
follows:
Step
1
Connect the personal computer (PC) to the LA PORT of the
IDU using an RS-232C cable as shown in Fig. 3-7,
2
Turn on the power on the PC. Then, operate the communication
software (e.g. MS Hyper Terminal),
3
Press the "CTRL" and "D" keys at the same time,
4
Enter the specified password from the keyboard and press the
"Enter" key,
Password
5
Press the "0" key and "Enter" key,
Password
Change password? (no:0 / yes:1) :
6
Following menu items are displayed,
1.
Setting
2.
Maintenance
3.
Monitoring
99. Exit
Select function No. :
7
Press the "3" key and "Enter" key, then, following menu is
displayed,
For 1+0 System
Monitoring
1.
Monitoring voltage
2.
Monitoring voltage (continuance mode)
3.
Alarm/Status
4.
Inventory
00. Menu
99. Exit
Select item No. :
Procedure
:
: ********
ROI-S04488