WFS709TP ProSafe Smart Wireless Switch Hardware Installation Guide
For PoE, the port should be connected directly to the intended device with no intervening
hubs, routers, switches, or other network equipment.
Connection to a regular 10/100 Mbps Ethernet segment
This requires a 4- or 8-conductor Category 5 UTP Ethernet cable with an RJ-45 male
connector. The port detects MDI/MDX and automatically adjusts for straight-through or
crossover cables.
The maximum length for FE cables is 100 meters (325 feet).
Cables that run through plenums or air-handling spaces as described in NEC (2002) Article
300.22(C) should be suitable under NEC Article 800.50 and marked accordingly for use in
plenums and air-handling spaces with regard to smoke propagation, such as CL2-P, CL3-P, MPP,
or CMP.
Note: Be sure to install cables in accordance with all applicable local regulations and
practices.

GE Uplink Port

1000BASE-T (Copper) GE Cable
Table A-1
lists the cable characteristics for the 1000BASE-T GE uplink port.
Table A-1. Copper GE Cable Characteristics
Item
Specification
Cable
Category 5 UTP
Connector
RJ-45
Range
Up to 100 m (325 feet)
A-2
v1.0, May 2007