Specifications - Tripp Lite Data Shield Owner's Manual

Network dataline surge suppressors
Table of Contents

Advertisement

Available languages

Available languages

SPECIFICATIONS

All surge suppressors listed have component response times of less than 1 picosecond.
Model:
DRS232
DNET1
DSUT1CSU
DTEL2
DB9
DB25
DB25-ALL
D10B2
DCATV
Call Tripp Lite Customer Support at (773) 869-1234 for additional applications.
200810167 93-2858.indd 3
Description:
RJ45/RJ11 protector for
100Base-T4, RS232 on twisted Pair
(wires 1-8) or ISDN "S/T" interfaces.
Supplied with a 4" RJ45 patch cable.
RJ45 100Base-T, 10Base-T,
Token Ring, RS422, AS400/Sys3x
protector for NICs, hubs, routers,
etc. Supplied with 4" RJ45 patch
cable.
RJ45/RJ11 protector for nonspan
powered T-1 equipment, digital data
service CSUs/DSUs, ISDN "U"
interfaces or other digital lines.
Supplied with 4" RJ45 patch cable.
RJ45/RJ11 for modems, answering
and fax machines. Supplied with
4" RJ11 patch cable.
Serial DB9 RS232 protector for male
or female ports of data terminal and
computing equipment including PCs,
modems, etc. (Any male or female
9-pin port). Male/Female genders
are reversible with reversible
thumbscrews.
Serial DB25 RS232 protector
(wires 1-8, 20) for male or female
ports of data terminal & computing
equipment including PCs, printers,
modems, etc. Male/Female genders
are reversible with reversible
thumbscrews.
DB25-ALL: Serial DB25 RS232
protector (pins 1-25) for any 25-pin
male or female DTE/DCE ports.
Male/Female genders are reversible
with reversible thumbscrews.
10Base-2 thin coax protector (BNC
m/f). Also protects IBM 3270 and
CCTV lines.
Coaxial protector for TVs, VCRs, pro
video supplied by CATV ("F" m/f).
Nominal
Clamping Voltage:
18 volts, protecting
wires 1-8
7.5 volts, protecting
wires 1-8
60 volts, protecting
wires 1-8
260 volts, protecting center
4 wires (2 CO-lines)
18 volts, protecting pins
1-9 and chassis
18 volts, protecting pins
1-8, 20 and chassis
18 volts, protecting pins
1-25 and chassis
7.5 volts, protecting center,
shield and chassis
7.5 volts, protecting center
and shield conductors
3
Peak Pulse
Current:
1340 amps
750 amps
200 amps
250 amps
340 amps
340 amps
340 amps
750 amps
750 amps
12/16/2008 9:58:51 AM

Advertisement

Table of Contents
loading

Table of Contents