S Video Out Chroma Level Adjustment; (Vc-308 Board); Video Out Y, Chroma Level Check (Vc-308 Board) - Sony DCR-IP210 Adjustment

Hide thumbs Also See for DCR-IP210:
Table of Contents

Advertisement

DCR-IP210/IP210E/IP220/IP220E

3. S VIDEO OUT Chroma Level Adjustment

(VC-308 Board)

Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: The data of page: 0, address: 10 must be "00".
Adjusting method:
Order Page Address Data
1
0
01
2
3
02
3
3
00
4
3
07
5
C
95
6
C
95
7
C
96
8
C
96
9
3
00
10
3
02
11
0
01
12
Note2: For the bit values, refer to "6-4. SERVICE MODE", "4-3. 3. Bit
value discrimination".
0.28 µsec (NTSC)
0.23 µsec (PAL)
Camera
Arbitrary
Chroma signal terminal of S VIDEO
plug of A/V jack (75Ω terminated)
External trigger: Y signal terminal of
S VIDEO plug of A/V jack
Oscilloscope
C
95, 96
Cr level:
A = 714 ± 14mV(NTSC)
A = 700 ±14mV(PAL)
Cb level:
B = 714 ± 14mV(NTSC)
B = 700 ± 14mV(PAL)
Burst level: C = 286 ± 6mV(NTSC)
C = 300 ± 6mV(PAL)
Procedure
01
Set the data.
FE
Set the data.
07
Set the data, and press PAUSE button.
Check that bit1 of the data
changes to "1". (Note2)
Change the data and set the Cr signal
level (A) to the specified value.
Press PAUSE button.
Change the data and set the Cb signal
level (B) to the specified value.
Press PAUSE button.
00
Set the data, and press PAUSE button.
00
Set the data.
00
Set the data.
Check that the burst signal level
(C) satisfies the specified value.
H
A
B
0.28 µsec (NTSC)
0.23 µsec (PAL)
H
Fig. 6-3-7.

4. VIDEO OUT Y, Chroma Level Check (VC-308 Board)

Mode
Subject
Measurement Point
Measuring Instrument
Specified Value
Note1: The data of page: 0, address: 10 must be "00".
Adjusting method:
Order Page Address Data
1
3
2
3
3
3
4
5
6
3
7
3
Note2: For the bit values, refer to "6-4. SERVICE MODE", "4-3. 3. Bit
value discrimination".
A
C
6-62
Camera
Arbitrary
Video terminal of VIDEO plug of A/V
jack (75Ω terminated)
Oscilloscope
Sync level: A = 286 ± 18mV(NTSC)
A = 300 ± 18mV(PAL)
Burst level: B = 286 ± 18mV(NTSC)
B = 300 ± 18mV(PAL)
Procedure
02
FE
Set the data.
00
07
Set the data, and press PAUSE
button.
07
Check that bit1 of the data
changes to "1". (Note2)
Check that the sync signal level
(A) satisfies the specified value.
Check that the burst signal level
(B) satisfies the specified value.
00
00
Set the data, and press PAUSE
button.
02
00
Set the data.
H
Fig. 6-3-8.
B