Capacitors

The DC link of the drive contains several electrolytic capacitors. Operating time, load, and
surrounding air temperature have an effect on the life of the capacitors. Capacitor life can
be extended by decreasing the surrounding air temperature.
Capacitor failure is usually followed by damage to the unit and an input cable fuse failure,
or a fault trip. If you think that any capacitors in the drive have failed, contact ABB.

Reforming the capacitors

The capacitors must be reformed if the drive has not been powered (either in storage or
unused) for a year or more. The manufacturing date is on the type designation label. For
information on reforming the capacitors, see Capacitor reforming instructions (3BFE64059629
[English]) in the ABB Library (https://library.abb.com/en).

Control panel

For detailed information on the control panel, see ACx-AP-x assistant control panels user's
manual (3AUA0000085685 [English]).

Cleaning the control panel

Use a soft damp cloth to clean the control panel. Avoid harsh cleaners which could scratch
the display window.

Replacing the control panel battery

For instructions on how to replace the control panel battery, see ACx-AP-x assistant control
panels user's manual (3AUA0000085685 [English]).

Replacing the ZCU-14 control unit battery

WARNING!
Obey the safety instructions of the drive. If you ignore them, injury or death, or
damage to the equipment can occur.
If you are not a qualified electrical professional, do not do installation or
maintenance work.
1. Stop the drive and do the steps in section
you start the work.
2. Remove the M4×8 [T20] screws at the ends of the control unit.
3. To see the battery, remove the XD2D terminal block.
4. Carefully lift the edge of the control unit cover on the side with the I/O terminal blocks.
5. Carefully pull the battery out of the battery holder.
6. Carefully put a new CR2032 battery into the battery holder.
7. Close the control unit cover.
8. Tighten the M4×8 [T20] screws.
9. Install the XD2D terminal block.
Electrical safety precautions (page 18)