Download Print this page
GE Monogram ZPK1 Installation Instructions
GE Monogram ZPK1 Installation Instructions

GE Monogram ZPK1 Installation Instructions

Icemaker drain pump

Advertisement

Quick Links

Installation
Instructions
Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death
or electrical shock.
IMPORTANT: Connect drain pump to house drain
in accordance with all state and local codes and
ordinances.
Note:
• This drain pump is designed to pump water to a
maximum height of 10 feet.
• To minimize condensation on the drain tube,
insulate the full length of the tube from the pump to
the drain.
If Icemaker Is Presently Installed:
• Push the selector switch to OFF.
• Unplug icemaker or disconnect power.
• Shut off water supply. Wait 5 to 10 minutes for the ice
to fall into the storage bin. Remove all ice from the
bin.
• Unscrew the drain cap from the bottom of the water
pan located inside the storage bin. Allow water to
drain completely. Replace the drain cap.
Disconnect Water Inlet
For connection in Front at Water Valve:
• Remove the 2 screws in the front lower access panel
and the 2 screws from the base grille area. Pull panel
forward to remove.
WARNING
Icemaker Drain Pump
Kit Contents:
• Drain Pump
• Drain Tube, 5/8" ID x 4-1/2" (bin to pump reservoir inlet)
• Drain Tube, 3/8" ID x 10 ft. (pump to house drain)
• Vent Tube, 3/8" ID x 32" (pump to cabinet back)
• 3 Cable Clamps (Secures vent tube to back of product)
• 5 Screws, #8 x 1/2" (secures vent hose clamps to back of cabinet
and pump to base plate)
• 2 Hose Clamps, 1/2" (secures vent and drain tube to pump)
• Hose Clamp, 5/8" (secures drain tube to bin)
Water
Inlet
Water
Outlet
• Disconnect the water inlet line from the water valve.
• If the icemaker is installed between cabinets, pull
icemaker out of the opening.
1/4" Copper Tubing
1/4"
Compression Nut
Icemaker Connection
For Connection at Rear of Icemaker:
• Pull icemaker forward.
• For compression nut, diconnect water line as shown.
• For union between copper tubing, disconnect union.
ZPK1
Tubing
Clamp
Ferrule
(Sleeve)
PROCEED TO STEP 1

Advertisement

loading

Summary of Contents for GE Monogram ZPK1

  • Page 1 Installation ZPK1 Icemaker Drain Pump Instructions WARNING Kit Contents: • Drain Pump Electrical Shock Hazard • Drain Tube, 5/8" ID x 4-1/2" (bin to pump reservoir inlet) • Drain Tube, 3/8" ID x 10 ft. (pump to house drain) Disconnect power before servicing. •...
  • Page 2 STEP 1 Remove Original Parts • Remove the 2 screws in the front lower access panel 5/8" Hose Clamp and the 2 screws from the base grille area. Pull to remove. Set aside screws and panel. • Unplug power cord from rear cover. Drain Tube (Bin to Pump) Remove Screws...
  • Page 3 STEP 4 Install Bin Drain Tube Connect Bin Drain Tube A. Attach drain tube from bin to pump with original hose clamp from old drain tube. B. Secure the pump to the base with the 2 supplied screws. Pump Mounting Screws STEP 5 Secure Vent Tube •...
  • Page 4 STEP 6 Connect Water Supply For connection in Front at Water Valve: For Water Connection at Rear: Vent Hose From Drain Pump Drain Hose From Drain Pump Water Water Supply Line Line Access Holes • Feed water supply tubing through one of the two access holes in the rear cover.