Genesis
Installation Overview
When you receive your Genesis™ DM Monitor, carefully remove each
piece of equipment from the box. Save the carton and packing materi-
als in case you need to return any of the contents. As you inventory the
contents of the box, check each piece of equipment for damage.
Your package should include the following items:
• Genesis DM Monitor
• Oximeter (SpO2) Finger Sensor (optional)
• Scale and scale cable
• Phone cord and duplex jack
• Blood pressure cu
• AC adapter (power supply)
• Blood pressure hose
• Power strip
Be sure to read the Genesis DM Clinician Guide before using your
monitor. The manual contains important instructions, warnings, and
cautions that should be reviewed before use.
HomMed Customer Service
Toll-free: 888-353-5404
Phone:
262-252-5840
Fax:
262-252-5795
Web:
www.hommed.com
DM Monitor Quick Setup Guide
Setting Up Your
Genesis DM Monitor
It is important to set up the Genesis DM
Monitor in an area where it can success-
fully measure vital signs and / or transmit
results. If you will be using any accessory
devices, make sure that there will be
enough room for you to attach them
without any di culty. To determine a
suitable location, consider the following:
Monitor Setup
Place the monitor on a at, stable, and
uncluttered surface, near a closed
window on an outside wall. Be certain
the monitor is easily accessible, and that
a bed, chair, or other seating is available. Make sure that you can easily
attach any peripheral devices.
Scale Setup
Find a PERMANENT spot for the scale where you can easily stand on it. Be
certain that the scale is placed on a solid, at surface that provides
adequate stability. The scale should not be moved.
CAUTION - READ CAREFULLY
DO NOT
Power up until the monitor is set up, and all equipment is
properly attached.
DO NOT
Block the vents on the Genesis DM Monitor. The monitor
should have a two-inch rear clearance.
DO NOT
Use an electrical wall outlet controlled by a light switch.
DO NOT
Place near sources of water (sinks or bathtubs).
DO NOT
Place on or near a heat source (stove, replace, heaters,
heat vents, etc.)
DO NOT
Place the Genesis DM Monitor on top of, or next to, electri-
cal equipment (for example, a television or microwave).
NOTE
When absolutely necessary to place the monitor next to an
electrical device, verify that the monitor works properly.
Customer Service 24/7/365
1-888-353-5054
1
Genesis DM Front Panel
BP
SPO2
BPM
2
WT
3
4
5
Displays blood pressure as systolic and diastolic in mmHg
1
Green START key starts a blood pressure reading;
2
Enters/exits Setup Mode (pressed with YES key)
Red STOP key stops blood pressure reading and de ates the cu
3
Gray MANUAL key enters Manual Mode; Exits a menu in Setup Mode
4
Scale displays weight
5
Blue RETEST key starts an unscheduled monitoring session;
6
Selects a menu option in Setup Mode
Black NO key records a "no" answer; DOWN scroll key in Setup Mode
7
White YES key records a "yes" answer; UP scroll key in Setup Mode
8
Enters/exits Setup Mode (pressed with START key)
BPM displays the pulse rate. If optional Sp02 is attached, a pulse strength bar
9
appears next to the pulse rate number during Sp02 collection.
%SpO2 Displays oxygen saturation measurement (for optional device)
10
2
1
Genesis DM Rear Panel
Only use AC Adapter
!
Input 24V
0.5A
MODEM
COM-A
POWER
SCALE
Modem connection for a standard (RJ11) phone cord
1
The COM-A port is for a Wireless GPRS modem or external devices that connect to
2
the Genesis DM monitor.
The power jack is for the AC adapter which powers the monitor.
3
The rst isolated port is a dedicated scale COM port. COM1 and COM2 allow a
4
patient to use an external device connected to the monitor.
P4500EN.01 11-15-2007 ©2007. Honeywell HomMed.
10
9
8
7
6
3
4
COM1
COM2

Advertisement

loading

Summary of Contents for Honeywell HomMed Genesis DM

  • Page 1 The rst isolated port is a dedicated scale COM port. COM1 and COM2 allow a Web: www.hommed.com patient to use an external device connected to the monitor. P4500EN.01 11-15-2007 ©2007. Honeywell HomMed.
  • Page 2 For a list of error codes, refer to the Genesis DM Clinician step on the scale, pressure is placed on all four feet that contain the load cells. Guide. A serious error will halt the system. If a fatal error occurs, contact Honeywell Attaching the oximeter You can adjust the height of the scale by screwing the feet in or out.