4. Remove the drum from the assembly.
5. Grasp the rubber valve seat between your thumb and forefinger and lift it upward to remove the valve seat
from the valve. The seat is located inside the humidifier housing at the water valve opening. See Fig. 2.
6. Raise up the float and remove the water pan.
BEARING END OF
COVER
DRUM SHAFT
HUMIDIFIER
HOUSING
WATER PAN
WATER VALVE
OPENING
Fig. 1. Removing Drive Assembly
LIFT THE RUBBER VALVE SEAT UPWARD
TO REMOVE IT FROM THE VALVE
Fig. 2. Float Valve Assembly
HE120 BY-PASS DRUM HUMIDIFIER
DRUM
ASSEMBLY
M12252A
M13617
3
69-1110EF—03