Download Print this page

Waldoor UWS User Instruction

Sliding door operator

Advertisement

Quick Links

WINTERSTAND
IN /UIT
Use of the programme switch (PGS)
Winter position
Automatic
Exit
Closed
(optional locked)
open
Sequence function
Display:
-8- General fault. See the display in the PCB
-A - Battery fault. (Press 1 x on "reset". The battery
test is repeated after 1 hour, etc.).
-0- Same as -A- on older versions type 2. (Visible
on the PGS after switching on the line power).
-E- Pull open cord defect.
By pushing shortly the RESET button on the PGS,
the computer tries to repair a possible fault
Hard Reset:
1- Switch off and on again the 230V or
2- ( ³ 1.90) Press reset 5 sec. until all led's
are flashing and then 5 sec. on the
sequence button until all led's are off.
Accustraat 21, P.O. Box 94, 3900 AB, Veenendaal (NL), Tel.: +31 (0)318-532333, Fax: +31 (0)318-532339
Traderegister 30080679, E-mail: waldoor@waldoor.nl, Internet: www.waldoor.nl
User Instruction Waldoor
Sliding Door Operator UWS and WM1-A
Display
Reset button
W A L D O O R A U T O M AT I C D O O R S
®
1. Line cable (230V AC with earth)
2. Motion detector
3. Cover
4. Fixed side panel
5. Door leaf
6. Photocells (1 or 2 sets)
7. Programme switch (PGS)
8. 3-Position programme selector switch
9. Night switch (key or pushbutton)
10. Handle (optional) for hermetical doors
11. Manual unlocking (optional)
Programming
Wo = winter open width
So = open speed
Sc = close speed
To = open time
Push RESET ± 5 sec. until all led's
·
are flashing.
Press repeatable on the desired
·
button (So, Sc of To) and select the
right value 0 (min.) until 9 (max.)
Close by pressing RESET.
·
Learning cycle:
During a delay time of
shows a " 3 " (or a " 2 " on older versions) and
all led's are on.
After these 5 seconds all led's are off except
AUTOMATIC.
The door will close now maximum on the
lowest speed the computer has found.
After that the door will fully open on the
lowest speed. During this opening cycle a
brake test is carried out.
After the door has fully opened against the
end stop the door will close on normal speed
and is ready to use.
5 sec. the PGS

Advertisement

loading

Summary of Contents for Waldoor UWS

  • Page 1 ® User Instruction Waldoor Sliding Door Operator UWS and WM1-A 1. Line cable (230V AC with earth) 2. Motion detector 3. Cover 4. Fixed side panel 5. Door leaf WINTERSTAND 6. Photocells (1 or 2 sets) IN /UIT 7. Programme switch (PGS) 8.
  • Page 2 ® • The Waldoor UWS automatic sliding door operators are designed to open and close sliding door leafs as reliably as possible and to grant persons a safe passage. To prevent persons for dangerous situations it is not advisable to stand continuously between the doors despite of a built in safety reverse.

This manual is also suitable for: