Fitting the new Processor Board
Position the new Processor Board as shown in figs 3 or 4 as appropriate.
Connect the inverter cable. The connector must be properly orientated before insertion into J13. Failure to do so
will bend the pins and may permanently damage the new processor board.
Connect the touch screen cable, ensuring there are no twists in the cable.
Connect the display connector. On the QX recorder the top of the display connector should be pulled up, the
cable inserted and the top of the connector pushed down to clamp the cable in place. The QX recorder display
cable must be fitted with the blue insulator towards the back of the recorder. The SX recorder display cable is
simply pushed on, but must be correctly aligned.
Fold the processor board up, being careful not to trap any of the cables and align the processor board
connector with the mother board. Push the processor board on and ensure the connectors are fully mated.
Re-fit the four M3 screws.
Re-fit the case and back panel assembly
Fit the case by carefully sliding it on from the rear of the recorder. Ensure the case is orientated correctly, with
the power supply cooling slots on the top of the recorder.
Slide the case/back panel fully forward ensuring that no internal cables get trapped between the case and front
bezel.
The case should sit flat on the back of the front bezel.
Re-fit the four screws that secure the case. (QX M3 x 6mm, SX M4 x 8mm)
Screw should be tightened to a torque of 120cNm.