Construction, Installation And Environmental Conditions - Siemens SCALANCE X-300 Series Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300 Series:
Table of Contents

Advertisement

Technical specifications
8.5 Technical specifications for X-300EEC
8.5.1

Construction, installation and environmental conditions

Table 8-38
Device version
(power supply)
1 24 VDC power supply unit ● Without clip:
2 x 24 VDC power supply
units
1 x power supply unit
100 to 240 VAC / 60 to 250
VDC
2 x power supply units
100 to 240 VAC / 60 to 250
VDC
Table 8-39
Installation options
Possible only with adapter (must be provided by installers).
1)
Wall mounting possible with suitable wall support.
2)
With mounting support
3)
Table 8-40
Storage/transport tem‐
perature
-40 °C to +70 °C
The IE Switch was type tested for 16 h at +85 °C.
1)
174
Construction
Dimensions (W x H x D)
60 × 125 × 123 mm
● With clip:
216 × 203 × 99 mm
● Without clip:
60 × 125 × 123 mm
● With clip:
216 × 203 × 99 mm
● Without clip:
60 × 125 × 123 mm
● With clip:
216 × 203 × 99 mm
● Without clip:
60 × 125 × 123 mm
● With clip:
216 × 203 × 99 mm
Installation options
● DIN rail
● S7-300 standard rail
● Wall
● 19" rack
Permitted ambient conditions
Operating temperature
-40 °C to +70 °C
Weight
1800 g
2030 g
1850 g
2120 g
1)
2)
3)
Max. relative humidi‐
ty in operation at 25
°C
<= 95% (no conden‐
1)
sation)
Operating Instructions, 11/2019, A5E01113043-24
Degree of protec‐
tion
IP30
IP30
IP30
IP30
Max. ambient temperature
at operating altitude
Max. 65 ℃ as of 2000 m
Max. 60 ℃ as of 3000 m
SCALANCE X-300

Advertisement

Table of Contents
loading

Table of Contents