Samsung AC MXADKH Series Installation Manual page 11

Table of Contents

Advertisement

Model
Type
Indoor unit
AC052MXADKH/EU
AC052MN4DKH/EU
AC052MXADKH/EU
AC052NN4DKH/EU
AC052MXADKH/EU
AC052MNNDKH/EU
AC052MXADKH/EU
AC052NNNDKH/EU
AC052MNMDKH/EU AC052MXADKH/EU
AC052MXADKH/EU
AC052MNLDKH/EU
B
AC052MXADKH/EU
AC052MNCDKH/EU
AC052MXADKH/EU
AC052MNJDKH/EU
AC052MXADKH/EU
AC052MNADKH/EU
AC060MXADKH/EU
AC060MNNDKH/EU
AC060MXADKH/EU
AC060NNNDKH/EU
AC060MNMDKH/EU AC060MXADKH/EU
AC071MXADKH/EU
AC071MN4DKH/EU
AC071MXADKH/EU
AC071NN4DKH/EU
AC071MXADKH/EU
AC071MN4PKH/EU
AC071MXADKH/EU
AC071MNNDKH/EU
AC071MXADKH/EU
AC071NNNDKH/EU
C
AC071MNMDKH/EU AC071MXADKH/EU
AC071MXADKH/EU
AC071MNLDKH/EU
AC071MXADKH/EU
AC071MNCDKH/EU
AC071MXADKH/EU
AC071MNADKH/EU
AC071MXASEH/EU
AC071MNMSEH/EU
AC100MXASEH/EU
D
AC100MNMSEH/EU
NOTE
1 Voltage range
• Units are suitable for use on electrical systems
where voltage supplied to unit terminal is not
below or above listed range limits
2 Maximum allowable voltage variation between
phases is 2%.
3 Wire size & type must comply with the applicable
local and national code.
• Wire size: Based on the value of MCA.
• Wire type: 60245 IEC57(IEC) or H05RN-
F(CENELEC) grade or more.
Outdoor unit
Rated
Outdoor unit
Hz
Volts
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
50
220 to 240 198
Input current (Amperes)
Voltage range
Outdoor unit
Min.
Max.
Cooling
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
20
264
22
4 MFA is used to select the circuit breaker and the
ground fault circuit interrupter (earth leakage circuit
breaker).
5 MCA represents maximum input current.
• MFA represents capacity which may accept MCA
• Abbreviations
MCA: Min. Circuit Amps. (A)
MFA: Max. Fuse Amps. (A)
Power supply
Indoor
Total
MCA
unit
Heating
20
1.0
21.0
21.0
20
1.0
21.0
21.0
20
1.0
21.0
21.0
20
1.0
21.0
21.0
20
2.5
22.5
22.5
20
1.7
21.7
21.7
20
1.0
21.0
21.0
20
1.0
21.0
21.0
20
1.6
21.6
21.6
20
1.0
21.0
21.0
20
1.0
21.0
21.0
20
2.5
22.5
22.5
20
1.0
21.0
21.0
20
1.0
21.0
21.0
20
1.5
21.5
21.5
20
1.0
21.0
21.0
20
1.0
21.0
21.0
20
2.5
22.5
22.5
20
1.7
21.7
21.7
20
1.0
21.0
21.0
20
1.6
21.6
21.6
20
3.5
23.5
23.5
22
3.5
25.5
25.5
MFA
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
28.0