Flange Back Check; Picture Frame Setting - Sony DCR-TRV40 Service Manual

Digital video camera recorder
Table of Contents

Advertisement

9. Flange Back Check

Subject
Siemens star
(2.0m from the front of the lens)
(Luminance : approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at the TELE end and WIDE
end.
Note1: The data of page: 0, address: 10 must be "00".
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT (Menu display) ........................................ OFF
Note2: When the auto focus is ON, the lens can be checked if it is focused
or not by observing the data on the page 1 of the adjustment remote
commander.
1)
Select page: 0, address: 03, and set data: 0F.
2)
Page 1 shows the state of the focus.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Checking method:
1)
Select page: 6, address: 40, and set data: 01.
2)
Select page: 6, address: 41, and set data: 01.
3)
Place the Siemens star 2.0m from the front of the lens.
4)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
5)
Shoot the Siemens star with the zoom TELE end.
6)
Turn on the auto focus.
7)
Check that the lens is focused (Note2).
8)
Select page: 6, address: 21, and set data: 10.
9)
Shoot the Siemens star with the zoom WIDE end.
10) Observe the TV monitor and check that the lens is focused.
Processing after Completing Adjustments:
1)
Select page: 6, address: 21, and set data: 00.
2)
Select page: 6, address: 40, and set data: 00.
3)
Select page: 6, address: 41, and set data: 00.
4)
Select page: 0, address: 03, and set data: 00.
DCR-TRV40/TRV40E/TRV50/TRV50E

10. Picture Frame Setting

Subject
Measurement Point
Measuring Instrument
Specified Value
Note1: The following adjustments should be carried out upon completion
of "Flange Back Adjustment".
Note2: The data of page: 0, address: 10 must be "00".
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Setting method:
1)
Adjust the zoom and the camera direction, and set to the
specified position.
2)
Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using "Color reproduction adjustment frame".
Check on the oscilloscope
1. Horizontal period
A=B
B
A
2. Vertical period
E
Check on the monitor TV (Underscanned mode)
Color bar chart picture frame
5-27
Color bar chart
(Color reproduction adjustment frame)
(1.5m from the front of the lens)
Video output terminal
Oscilloscope and TV monitor
A=B, C=D, E=F
C=D
C
D
Fig. 5-1-9.
E=F
F
V
Fig. 5-1-10.
Monitor TV picture frame
Fig. 5-1-11.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-trv40eDcr-trv50Dcr-trv50e

Table of Contents