Setting Values For Output; 13.5.1 Gas Setting Values - Bosch Worcester 2000 Series Installation And Maintenance Instructions Manual

Gas-fired condensing combi appliance
Table of Contents

Advertisement

13.5

Setting values for output

The maximum rated heat output can be reduced to up to 50 % of the
output range (service function 3-b1).
The minimum rated heat output can be increased to up to 50 % of the
output range (service function 5-A3).

13.5.1 Gas setting values

GC2000iW 25 C
Display
Heat Output
percentage %
[kW]
80
20.0
75
18.7
70
17.5
65
16.2
60
15.0
55
13.7
50
12.5
45
11.2
40
10.0
35
8.7
30
7.5
25
6.2
20
5.0
19
4.8
Table 38 GC2000iW 25 C
GC2000iW 30 C
Display
Heat Output
percentage %
[kW]
68
20.0
65
19.1
60
17.6
55
16.2
50
14.7
45
13.2
40
11.7
35
10.3
30
8.8
25
7.3
20
5.9
16
4.8
Table 39 GC2000iW 30 C
Worcester 2000 – 6 721 814 551 (2019/09)
Heat input
Gas flow rate [l/min]
[kW]
20.40
35.0
19.13
32.8
17.85
30.6
16.58
28.4
15.30
26.3
14.03
24.1
12.75
21.9
11.48
19.7
10.20
17.5
8.93
15.3
7.65
13.1
6.38
10.9
5.10
8.8
4.92
8.4
Heat input
Gas flow rate [l/min]
[kW]
20.4
35.0
19.5
33.5
18.0
30.9
16.5
28.3
15.0
25.7
13.5
23.2
12.0
20.6
10.5
18.0
9.0
15.4
7.5
12.9
6.0
10.3
4.92
8.4
Technical Specifications/Logs
77

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents