Modes of operation

Depending on the model of the cooker
hood, the following options are
available:
Extraction mode
The cooking vapours are drawn in by
the cooker hood. The air is passed via
the edge extraction panels through the
grease filters, cleaned and then directed
outside.
Non-return flap
The non-return flap is designed to
prevent the exchange of room and
outside air taking place when the
cooker hood is switched off.
The flap is closed when the cooker
hood is switched off.
When the cooker hood is switched on,
the non-return flap opens for the
cooking vapours to be blown directly
outside.
If the on-site ventilation system does
not have a non-return flap, the non-
return flap supplied must be fitted in the
exhaust socket in the motor unit.
14
Recirculation mode
(DUU 2900 conversion kit required)
The air is drawn in through the edge
extraction panels and then cleaned by
the grease filters. It is then directed into
the recirculation box where it is also
cleaned by the charcoal filters. The
cleaned air is then recirculated back
into the kitchen.
Operation with an external
motor
(EXT/EXTA model cooker hoods)
Cooker hoods designed for use with an
external motor have to be connected to
a Miele external motor located in a
position of your choice outside the
room. The external motor is connected
to the cooker hood by means of a
control cable and is operated via
Con@ctivty 2.0, by the control elements
on the cooker hood, or by the remote
control.