4.1.17 A scanning error occurred while scanning the image.
Step
Program malfunction
1
The maintenance mode function
2
"Acquire white level data and set
CIS scan area" are not set.
First side or second side CIS
3
unit failure
4
Main PCB failure
4.1.18 Email address has more than 64 characters.
The number of email addresses has exceeded the specified amount.
<User Check>
- Check the email address settings.
Step
1
Main PCB failure
4.1.19 Cannot connect to PC.
<User Check>
- Reconnect the USB cable.
- Replace the USB cable.
Step
1
Main PCB failure
Cause
Install the latest version of the firmware.
(Refer to
Execute the maintenance mode function
"Acquire white level data and set CIS scan
area". (Refer to
Replace the first side or second side CIS unit.
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
2-16
Remedy
"1.1" in Chapter
4.)
"1.3.5" in Chapter
Remedy
Remedy
5.)