8.1.4 Measures to take in the case of processing unit failure

!
If the processing computer fails due to an hardware error, BS2000 operations are no longer
possible.
8.1.5 Measures to take in the case of defective IOP, MCU, SVP, SCI, SPC, PCI
system components
If the IOP (Input Output Processor), MCU (Memory Control Unit), SVP (Service Processor),
SCI (System Control Interface), SPC (System Power Controller) oder PCI (Power Control
Interface) system components fails, you may not be able to continue working with the S120.
If the failure of one of these components causes a complete system failure, you can carry
out the following actions after consultation with the service department:
Ê
execute an IMPL (AU4-FRAME)
or
switch off the S120 (AU4-FRAME) and then restart it (control panel, SKP menu).
Ê
If the shutdown and subsequent IMPL occur without errors, the BS2000/VM2000 can be
restarted with the IPL.
94
If the CPU is defective, you must contact the service department.
Troubleshooting