Before operation
3.3.6
Changing acceleration and deceleration time of the motor (Pr. 7, Pr. 8)
Set in Pr. 7 Acceleration time a larger value for a slower speed increase and a smaller value for a faster speed increase.
Set in Pr. 8 Deceleration time a larger value for a slower speed decrease and a smaller value for a faster speed decrease.
Parameter
Number
7
Acceleration time
8
Deceleration time
Changing
Change the Pr. 7 Acceleration time setting from "5s" to "10s".
example
1.
Screen at powering ON
The monitor display appears.
2.
Press
to choose the PU operation mode.
3.
Press
to choose the parameter setting
mode.
4.
Turn
until
5.
Press
to read the currently set value.
"
" (5.0s (initial value)) appears.
6.
Turn
to change the set value to "
(10.0s).
7.
Press
to set.
46
Name
Initial Value
3.7K or less
5.5K, 7.5K
11K, 15K
3.7K or less
5.5K, 7.5K
11K, 15K
Operation
(Pr. 7) appears.
Turn
to read another parameter.
Press
to show the setting again.
Press
twice to show the next parameter.
Setting Range
5s
10s
0 to 3600s
15s
5s
10s
0 to 3600s
15s
PU indication is lit.
PRM indication is lit.
(The parameter number read previously
appears.)
"
Flicker ··· Parameter setting complete!!
Description
Set the motor acceleration time.
Set the motor deceleration time.
Pr. 20
Running
(60Hz)
frequency
Acceleration
Deceleration
Pr. 7
time
time
Pr. 44
Display
Time
Pr. 8