Specifications

6.1 Table of Specifications

6.1.1 General Specifications

 Specifications
Item
Rated operating voltage
Operating voltage range
Rated current
consumption
Allowable instantaneous
power-off time
Current consumption
increase of control unit
Ambient temperature
Storage temperature
Ambient humidity
Storage humidity
Breakdown voltage
(Note 2)
Insulation resistance
Vibration resistance
Shock resistance
Noise immunity
Operating condition
EU Directive applicable
standard
Overvoltage category
Pollution level
Weight
(Note 1): In the case of the unit of Ver.1.2 and after; 20 mA for the unit of Ver.1.1 or older.
(Note 2): Cutoff current: 5 mA (factory default setting).
6-2
Description
24 V DC
20.4 to 28.8 V DC (Unit input voltage)
AFP0RDA4:180 mA or less
AFP0RA21: 80 mA or less
AFP0RA42:120 mA or less
10ms
AFP0RAD4/ AFP0RAD8
AFP0RDA4
AFP0RA21/ AFP0RA42
0°C to +55°C
-40°C to +70°C
10 to 95%RH (at 25°C non condensing)
10 to 95%RH (at 25°C non condensing)
Between I/O terminal and control unit power supply
terminal / ground terminal
<AFP0RA21/AFP0RA42>
Between analog input terminal and analog output terminal
Between I/O terminal and control unit power supply
terminal / ground terminal
<AFP0RA21/AFP0RA42>
Between analog input terminal and analog output terminal
Based on JIS B 3502 and IEC 61131-2:
5 to 8.4 Hz, half amplitude 3.5 mm
8.4 to 150 Hz, constant acceleration 9.8 m/s
X, Y and Z axes, 10 sweeps (1 octave/mm)
Based on JIS B 3502 and IEC 61131-2
2
147 m/s
or more, X, Y and Z axes, 3 times
1000V [P-P] with pulse widths 50 ns, 1μs (using noise simulator)
(Applied to the power supply part of the control unit)
Must be free from corrosive gases and excessive dust.
EMC Directive: EN 61131-2
Category II
Pollution level 2
AFP0RAD4/ AFP0RA21
AFP0RAD8/ AFP0RDA4/ AFP0RA42
:45 mA or less (Note 1)
:10 mA or less
:10 mA or less
2
:Approx. 75 g
:Approx. 85 g
500 V AC for 1
minute
Min. 100 MΩ
(measured with a
500V DC megger)