Requirements
Requirements
Long Haul Requirements
Carrier Board Signaling Level Requirements
Environmental Requirements
2 - 4
The installation requires:
•
Backplane according to used carrier board:
– CompactPCI carrier board: CompactPCI (optional CompactPCI-H.110)
backplane system with power supply
– VMEbus carrier board: VMEbus (optional VMEbus-SCbus) backplane sys-
tem with power supply
•
Corresponding carrier board with at least one PMC slot
The two front-panel line interfaces in T1 mode on the SC-F and H.110-F variants
are DSX-1 type interfaces which means that in T1 mode, the interfaces do not sup-
port long haul required for public networks. To be able to operate the PPC/PMC-
8260/DS1 in a public network you need a CSU (channel service unit).
The PPC/PMC-8260/DS1 supports signaling levels 3.3V and 5V and therefore is a
universal PMC module. Make sure that your carrier board has a signaling level of
3.3V or 5V at the PMC interface.
The environmental values given in the table below must be tested and proven in the
used system configuration. Operating temperatures refer to the temperature of the
air circulating around the board and not to the actual component temperature.
Installation
PPC/PMC-8260/DS1