General; Specifications; Application; Operation - Honeywell WP241 Series Service Data

Dual air compressors
Table of Contents

Advertisement

GENERAL

This sheet contains maintenance and repair informa-
tion for the WP241 series air compressors. The WP241
Dual Air Compressor has two electric motor-driven pumps
mounted on a common storage tank, allowing automatic
alternating operation with standby capability.
IONS
PRESSURE RANGE: Cut-in pressure-70 lb/in 2 (483
kPa), Cut-out pressure -90 lb/in 2 (621 kPa).
Compressor
WP241 Y
No. of Cylinders
RPM Compressor
500
Displacement ft 3 /min
(l/min)
Delivery ft 3 /min.
(l/min)
at 70 to 90 lb/in 2
1.1 (31)
(483 to 621 kPa)
One unit only
T a n k Size Gal (l)
30 (114)
Intake
Size NPT-Compressor
1/4
Outlet Size-NPT-Compressor
1/4
Flywheel O.D. (in.)
10
2.8
Motor Pulley Pitch Dia. (in.)
Safety Valve-Receiver-NPT
4 oz (118 ml)
Crankcase Oil Capacity
Lubrication System
WP241Y
1/3
115/60/1
-48

APPLICATION

The WP241 Dual Air Compressors are used where
continual operation is a necessity. The motors are inter-
connected to operate on alternate cycles with standby
capability. Should one motor fail, be shut down for
O P E R A T I O N
Air is drawn through the intake filter of the operating
motor-pump unit(s), compressed, and stored in the tank.
As the control system consumes air, the tank pressure
drops. When tank pressure drops to 70 lb/in 2 (480 kPa),
75-7268
Table 1. WP241 Dual Air Compressor Specifications.
WP241B
WP241C
1 1
1
1
410
460
2.9 0 (82)
4.7 (13.3)
1.9 (54)
3.3 (93)
80 (303)
80 (303)
3/4
3/4
3/4
3/4
14
14
3.6
3.2
1/4
1/4
28 oz. (828 ml)
28 oz (828 ml)
Splash
WP241B
WP241C
(0.25)
1/2 (0 .37)
3/4 (0.56)
208/60/3
230/60/3
-56
-56
MAXIMUM AMBIENT TEMPERATURE: 104 F (57 C).
TANK CAPACITY: 30, 80, or 200 gallons (114,303, or
757 R).
WP241E
WP241F
WP241D
2
2
480
460
5.4 (153)
5.9 (269)
13.3 (377)
3.8 (108)
5.9 (167)
8.6 (144
80 (303)
80 (303)
80 (303)
1/2
3/4
1-1/4
1/2
3/4
1-1/4
12
14
16
3.2
3.6
3.6
1/2
1/4
1/4
22 oz (651 ml)
48 oz (1.4l)
2 qt (1.4l)
WP241D
WP241E
WP241F
1 (0.75)
1 - 1 / 4 ( 1 . 1 2 )
2 (1.49)
460/60/3
208/60/3
230/60/3
-143T
-145T
-145T
maintenance, or be unable to maintain minimum storage
tank pressure, the other motor provides backup by start-
ing automatically.
the motor energizes operating the compressor pump,
which restores tank pressure to 90 lb/in 2
tank pressure increases to 90 lb/in 2 (620 kPa), a pressure
switch stops the motor.
2
WP241G
WP241H
2
2
2
400
570
550
16.0 (453)
24.3 (688)
19.3 (547)
12.6 (357)
80 (303)
700 (757)
1-1/2
1
1-1/4
3/4
19.5
16
6.0
5.1
1/2
1/2
6 qt (5.7l)
2 qt (1.9l)
Pressure
Pump
WP241G
WP241H
3 (2.24)
5 (3.73)
460/60/3
460/60/3
-182P
-184T
(620 kPa). When
W P 2 4 1 J
2
61 0
40.0 (1l33)
30.0 (849)
200 (757)
2
1 - 1 / 4
19.5
6.6
1/2
6 qt (5.7l)
WP241 J
7-1/2 (5.60)
460/60/3