Service Specifications
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Service Test – 161 Cube Dispenser
Display shows the state of the Ice Auger Motor (ON or OFF).
NOTE: By pushing Actuator pad you can control state of the Ice Auger Motor without opening Ice Chute door.
Service Test – 163 Water Dispenser
Display shows the state of the Water Dispenser Valve (ON or OFF).
NOTE: By pushing Actuator pad or Front fill you can control state of Water Dispenser Valve.
Service Test – 164 External Ice Chute Door
Display shows the state of the External Ice Chute Door CL (closed) or OP (open).
NOTE: By pushing Actuator pad you can control state of External Ice Chute Door.
Service Test – 165 Dispenser Lamp
Display shows the state of the Dispenser Lamp (ON or OFF).
NOTE: By pushing Actuator pad or Bottle fill you can control state of dispenser lamp.
Service Test – 166 Internal Ice Chute Door Operation
Display shows the state of the Internal Ice Chute Door CL (closed) or OP (open).
NOTE: By pushing Actuator pad you can control state of Internal Ice Chute Door.
Service Test – 167 Cavity Heater Test
Display shows the state of the Cavity Heater (ON or OFF).
Service Test – 171 Actuator Pad
Display shows the state of the Actuator Pad (ON or OFF).
Service Test – 172 Bottle Fill
Display shows the state of the Bottle Fill (ON or OFF).
Service Test – 173 Ambient Light
Display shows light sensor measurement (Hi or Lo). Night light will turn on when light sensor measures Lo.
By changing the sensor's exposure to ambient light you can control the sensor measurement.
Service Test – 175 Dispenser Line
Display shows the state of the Dispenser Line (ON or OFF).
NOTE: By pushing Actuator pad or Bottle fill you can change state of Dispenser Line.
Service Test – 182 LED Indicator Operation
Press the Refrigerator Up Keypad
Press twice and LED will stop flashing.
Service Test – 183 Keypad Operation
Display shows a numeric or letter display indicating the last key pressed.
NOTE: Refrigerator Up/Down keypads have no effect when pressed and Freezer Up/Down keypads
remain operational.
16026830
!
WARNING
to show operation of LED Indicators. All LED Indicators will flash.
6