Download Print this page

Honeywell ADEMCO 5839 Installation And Setup Manual page 2

Wireless bidirectional alpha keyboard

Advertisement

Use this option to enroll the keypad in a 5883
transceiver.
NOTE:
If using more than one 5883 transceiver, make
sure you enroll all 5839 keypads in the same transceiver
(disconnect others from the system when enrolling). If
using the transmitter function for 5800TM compatible
devices, you must enroll the 5839 keypads in the
transceiver for which the transmitter (TM) function is
enabled.
= Press to advance to next prompt.
,
# = Advance to "Keys?" prompt (Step 5).
b. The prompt at right appears after
selecting "Y" from the previous
prompt.
, = Display keypad address prompt
# = Return to the "Setup?" prompt above.
When using...
Set 5839 for...
Vista
00
10SE/20SE
Family
00
Vista-15P/20P
Family †
01
(Check for
02
compatible
03
revisions that
appear on first
04
page.)
05
06
07
Vista-40 and
00-15
higher †
† The 5839 keypad must be programmed in the control as
an alpha keypad with no sounder suppression. Be sure
not to assign the same address to more than one device.
c. The prompt at right appears
after selecting "Y" from the
previous prompt.
Enter the 5839 keypad address (see table above).
, = Accept entry and enroll keypad in 5883.
# = Return to previous display.
d. The prompt at right appears
after pressing [,] from the
previous prompt.
This display remains for several seconds while the
5839 sends a setup request to the 5883 and receives
a reply. In some cases it may be necessary to send
additional setup requests by pressing the
To abort the enrollment, press [#], which returns the
system to the "ECP Addr?" prompt.
Otherwise, wait until the
prompt at right is displayed.
This display indicates the keypad has received the
site ID (nnnnnn) from the transceiver (5883).
, = Accept site ID and return to the "Setup?"
prompt
# = Reject site ID and return to setup menu.
5. a. The prompt at right appears
after selecting "N" from the
"Setup?" prompt (step 4.a.).
ECP Addr?
= Y # = N
,
Set Panel for...
Panel converts to
address 31
automatically.
16
17
18
19
20
21
22
23
00-15 (Program the
panel for the keypad
at the same
address.)
nn (00-15)
=Done # =End
,
Waiting for mesg
Setup? # = end
key.
,
ID: nnnnnn
=Done #=N
,
Keys
=Y #=N
,
- 2 -
, = Display next prompt.
# = Advance to "Sounds?" prompt.
b. The following prompt appears
after selecting "Y" from the
previous prompt.
, = Enables ABCD keys to transmit and returns to
"Keys?" prompt.
# = Disables ABCD keys and returns to "Keys?"
prompt.
6. a. The prompt at right appears
after selecting "N" from the
"Keys?" prompt.
, = Display "Stat/Warn/Chime" prompt.
# = Return to the initial "Options?" prompt.
b. The prompt at right appears
after selecting "Y" from the
previous prompt.
, = Enables the keypad to audibly annunciate
mode/status changes, warning sounds and
chime activation and return to "Sounds?"
prompt.
# = Disables audible annunciations and returns to
"Sounds?" prompt
EXITING FROM PROGRAMMING MODE
After all programming of the 5839 keypad is complete, it is
important to exit the programming mode. To do this, press
and hold down keys [1] and [3] at the same time for several
seconds until all 2 x 16 character locations on the LCD
indicate solid black rectangles, then release.
When the following display comes up,
press the # key. You have exited
5839 Rev.n.n.US
the programming mode.
Options?
=Y # =N
,
The display will now show:
Waiting for mesg
DELETING ALL ENROLLED WIRELESS KEYPADS
1. Remove power from the 5883 in the controls cabinet by
removing the 4-wire connector.
2. Set DIP switch 1 to OFF and DIP switch 8 to ON.
3. Reapply power and observe that the RED LED turns ON
immediately and remains ON.
4. Record the positions of DIP switches 1 through 8.
5. Set the 8 DIP switches to the opposite position recorded
in step 4.
6. Set the 8 DIP switches back to the same position
recorded in step 4. (All enrolled 5839s have been deleted
from the 5883 transceiver.)
7. Place DIP switch 8 back to the OFF position to return to
normal 5883 operation.
NOTES:
1. If you determine that the proper ECP address has not
been enrolled in the receiver, perform the above deleting
procedure and re-enroll all the 5839s in order to avoid
erroneous "CHECK" messages.
2. When in active mode, and a change of status of the
security system occurs (arming state or fault for instance),
the 5839 may take up to 20 seconds to display the change.
To obtain a real-time display of system status, press the [,]
key.
Send ABCD?
= Y # = N
,
Sounds?
= Y # = N
,
Stat/Warn/Chime
= Y # = N
,

Advertisement

loading