Air-conditioners for building application heat source unit

Advertisement

Air-Conditioners For Building Application
HEAT SOURCE UNIT
PQRY-P-YMF-C
INSTALLATION MANUAL
For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
INSTALLATIONSHANDBUCH
Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Veuillez lire le manuel d'installation en entier avant d'installer ce climatiseur pour éviter tout accident et vous assurer d'une utilisation correcte.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il condizionatore d'aria.
INSTALLATIEHANDLEIDING
Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert.
MANUAL DE INSTALAÇÃO
Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado.
E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™
°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ÂÁηٿÛÙ·Û˘ ÚÈÓ ·Ú¯›ÛÂÙ ÙËÓ
ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÌÔ‡.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным руководством по
установке до выполнения установки кондиционера.
MONTAJ ELK‹TABI
Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› monte etmeden önce bu elkitab›n› dikkatle okuyunuz.
Back to Index

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric CITY MULTI PQRY-P-YMF-C Series

  • Page 1 Air-Conditioners For Building Application HEAT SOURCE UNIT PQRY-P-YMF-C Back to Index INSTALLATION MANUAL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen. MANUEL D’INSTALLATION Veuillez lire le manuel d’installation en entier avant d’installer ce climatiseur pour éviter tout accident et vous assurer d’une utilisation correcte.
  • Page 2 [Fig. 4.0.1] [Fig. 5.1.1] = < 60° = > = > 1177 1227 A Heat source unit B 4-ø14 (Anchoring hole) C (Top view) [Fig. 5.1.2] [Fig. 6.1.1] D Anti-vibration pad E Concrete base [Fig. 5.2.1] A Water circulation pipe B Close valve 1150 C Close valve...
  • Page 3 (mm) [Fig. 7.2.1] Å High press pipe ı Low press pipe PQRY-P200 ø19.05 ø25.4 PQRY-P250 ø19.05 ø28.58 ø 25.4 (Flange) Ç Connection of heat ø 19.05 (Flare) sourse unit/BC controller ø 28.58 (Frange) (mm) Î Total capacity of indoor units ‰...
  • Page 4 [Fig. 9.2.1] A Power source [Fig. 8.4.1] B Transmission line L1 L2 L3 N M1M2 M1M2 S [Fig. 9.3.1] A Steel wire B Piping C Asphaltic oily mastic or asphalt D Heat insulation material A (51) E Outer covering B (01) (02) (05)
  • Page 5: Table Of Contents

    Contents 1. Safety precautions ..................5 7. Refrigerant piping installation ..............8 1.1. Before installation and electric work .......... 5 7.1. Caution ..................8 1.2. Precautions for devices that use R407C refrigerant ....5 7.2. Refrigerant piping system ............8 1.3.
  • Page 6: Before Getting Installed

    • Do not use a refrigerant other than R407C. • Install an leak circuit breaker, as required. - If another refrigerant (R22, etc.) is used, the chlorine in the refrigerant may - If an leak circuit breaker is not installed, electric shock may result. cause the refrigerator oil to deteriorate.
  • Page 7: Lifting Method And Weight Of Product

    4. Lifting method and weight of product [Fig. 4.0.1] (P.2) Caution: Be very careful to carry product. - Do not have only one person to carry product if it is more than 20 kg. - PP bands are used to pack some products. Do not use them as a mean for transportation because they are dangerous. - Tear plastic packaging bag and scrap it so that children cannot play with it.
  • Page 8: Pump Interlock

    3 Please consult with a water quality control specialist about water quality 6.4. Pump interlock control methods and water quality calculations before using anti-corrosive The heat source unit may become damaged if it is operated with no water circulat- solutions for water quality management. ing through the pipes.
  • Page 9: Caution For Piping Connection/Valve Operation

    E Open (Operate slowly) <Additional Charge> F Cap, copper packing Additional Liquid pipe size Liquid pipe size Liquid pipe size [Remove the cap and operate the valve stem. Always reinstall the cap after op- refrigerant charge Total length of Total length of Total length of + α...
  • Page 10: Thermal Insulation Of Refrigerant Piping

    Airtight test procedure Restriction 1. Nitrogen gas pressurization • If a flammable gas or air (oxygen) is used as the pressurization (1) After pressurizing to the design pressure (2.94 MPa) using nitrogen gas, let stand for about gas, it may catch fire or explode. one day.
  • Page 11: Wiring

    9. Wiring 9.1. Caution When using shielded wiring, connect shield ground of the indoor unit transmis- sion line to the earth screw ( ) and connect shield ground of the line between 1 Follow ordinance of your governmental organization for technical standard re- heat source units and the central control system transmission line to the shield lated to electrical equipment, wiring regulations and guidance of each electric (S) terminal of the central control terminal block (TB7) shield (S) terminal.
  • Page 12: Wiring Of Main Power Supply And Equipment Capacity

    <Permissible Lengths> 1 M-NET Remote controller • Max length via heat source units: L and L and L 500 m (1.25 mm or more) • Max transmission cable length: L and L and L and L and L and L 200 m (1.25 mm or more) •...
  • Page 13 This product is designed and intended for use in the residential, commer- cial and light-industrial environment. • Low Voltage Directive 73/23/EEC The product at hand is • Electromagnetic Compatibility Directive 89/ based on the following EU regulations: 336/EEC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.

This manual is also suitable for:

City multi pqry-p200ymf-cCity multi pqry-p250ymf-c

Table of Contents