iceqube IQ27000V Operation And Installation Manual

Intelligent electronic enclosure, thermal management systems

Advertisement

Intelligent Electronic Enclosure
Thermal Management Systems
IQ27000V
OPERATION AND INSTALLATION MANUAL
*** IMPORTANT ***
PLEASE READ this manual and follow the instructions for safe and satisfactory
installation and operation of this system. Keep this manual for future reference. Some
information may not apply to all systems.

Advertisement

Table of Contents
loading

Summary of Contents for iceqube IQ27000V

  • Page 1 Intelligent Electronic Enclosure Thermal Management Systems IQ27000V OPERATION AND INSTALLATION MANUAL *** IMPORTANT *** PLEASE READ this manual and follow the instructions for safe and satisfactory installation and operation of this system. Keep this manual for future reference. Some information may not apply to all systems.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Introduction Page Basic operation Page Figure 1: Flow Diagram Page Unpacking Inspection Page Pre-Installation Test Page Figure 2: 27000V unit Page Preparing the Enclosure Page Operating the System Page Programming the Controller Page Figure 3: Digital Controller Page Alarm Operation Page...
  • Page 3: Introduction

    INTRODUCTION: Ice Qube’s Thermal Management System, TMS, is designed to cool, dehumidify or heat the internal environment of modern electrical enclosures. Ice Qube offers efficient and aesthetically appealing packages that can be mounted on top or on the side of your enclosure. Our closed-loop circulation design protects your equipment from air-borne dust and contaminants which may hinder equipment operations, causing unnecessary down time.
  • Page 4: Pre-Installation Test

    The shipping container leaves the factory banded to a pallet with red arrows imprinted on the box. These red arrows should be pointing in the proper (upward) direction. The Ice Qube TMS is position sensitive and should remain in an upright position at all times. If the Ice Qube air conditioner should arrive not banded to a pallet and not in the proper upright position with red arrows pointing upward, the shipment may have been damaged and you may wish to consider contacting the freight carrier for instructions on filing a claim.
  • Page 5: Preparing The Enclosure

    connected has the proper capacity. After noting the above, connect power from a properly grounded electrical connection. The use of an extension cord is not recommended NOTE: If any unusual noise or vibration is present during the testing procedure, immediately disconnect the power and inspect the unit for the cause of the noise or vibration.
  • Page 6: Operating The System

    PREPARING THE ENCLOSURE: -continued- 3. Outline the modifications for the enclosure with a marking pencil. Note the bolt hole locations, the cutouts for the inlet and outlet air streams, the power connection and the locations for any optional equipment. Additional cable openings may be required for units with optional heating or alarm outputs, or for units connected to a network communications link.
  • Page 7: Programming The Controller

    If the heat load within the enclosure is less than the cooling capacity of the Ice Qube system, the temperature on the digital display will begin to decrease. When the temperature inside the enclosure decreases 7 degrees Fahrenheit below the “Cooling on” setpoint, the compressor and the condenser blower will cycle off.
  • Page 8 PROGRAMMING THE CONTROLLER: -continued- To change the factory default settings, enter the programming code sequence: “1 Adjust-up” arrow “2 Adjust-down” arrow “3 Select” “4 Exit” After pressing the above sequence the program LED should illuminate along with three alternating flashing boxes on the display face, indicating the code was accepted. If no selection is made within one minute, the system returns to the normal operating mode.
  • Page 9: Alarm Operation

    PROGRAMMING THE CONTROLLER: -continued- Press the “3 Select” button to continue. The “C” LED flashes and the display shows either “F” for degrees Fahrenheit or “C” for degrees Celsius. Press the “1 Adjust-up” arrow or “2 Adjust-down” arrow to toggle the mode as desired. Press the “3 Select”...
  • Page 10: Maintenance

    ALARM OPERATION: - continued - 2. The condenser temperature is above the condenser alarm setpoint: The alarm LED lights, the display flashes the condenser temperature, and the audible alarm sounds (if activated). The condenser temperature must fall four degrees Fahrenheit (two degrees Celsius) before the alarm will reset.
  • Page 11 To clean the system cabinet, simply wipe it with a damp, lint free cloth. A mild soap solution may be used if necessary. All current documentation and cut out templates can be found on our website at www.iceqube.com - 11 - QD-ENG-40 REV.3...
  • Page 12: Trouble Shooting

    TROUBLE SHOOTING: Contact Ice Qube if the air conditioning system should fail to operate satisfactorily during the first year of operation. DO NOT remove the cover without first notifying the factory. Removal of the cover will immediately void the warranty. If an operating problem should occur, please review the items outlined in the following “Trouble Shooting Check List”.
  • Page 13: 230Volt

    WIRING SCHEMATIC DIAGRAM – 230 volt - 13 - QD-ENG-40 REV.3...
  • Page 14: 480Volt

    WIRING SCHEMATIC DIAGRAM – 480volt - 14 - QD-ENG-40 REV.3...
  • Page 15: Drawing One

    SPECIFICATION DRAWING ONE - 15 - QD-ENG-40 REV.3...
  • Page 16: Drawing Two

    SPECIFICATION DRAWING TWO All current documentation and cut out templates can also be found on our website at www.iceqube.com - 16 - QD-ENG-40 REV.3...
  • Page 17: Warranty

    Standard Warranty Policy Ice Qube, Inc. ("Ice Qube") warrants that the products manufactured by Ice Qube (the "Products") are free of defects in material and workmanship which impair the operation of the Products, under normal and proper use and service, for a period of one (1) year from the date of shipment FCA from Ice Qube’s facility located in Greensburg, Pennsylvania (the "Standard Warranty").
  • Page 18 Ice Qube's advice relating to the technical usage of the Products or the intellectual property rights of others, whether provided orally or in writing or through the provision of test results, is given in accordance with Ice Qube's best knowledge at that time, but shall at all times be deemed to be non- binding.

Table of Contents