Assembly - RIDGID R860424 Operator's Manual

18 v hybrid forced air propane heater
Table of Contents

Advertisement

Available languages

Available languages

ASSEMBLY

CONNECTING THE PROPANE CYLINDER
See Figures 2 - 5, pages 12 - 13.
To connect:
 Using an adjustable wrench (not provided), screw the
open end of the propane hose to the propane inlet on
the heater. Tighten securely.
NOTE: For first time use, remove the rubber protector
cap that protects the propane inlet during shipment.
 Make sure the handwheel on the propane cylinder is in
its full off position, then remove the cap from the cylinder
valve.
 Hold the regulator firmly and insert the nipple into the
cylinder valve.
NOTE: Nipple must be centered in the cylinder valve.
 Holding coupling nut and regulator as shown, turn cou-
pling nut counterclockwise and tighten by hand, taking
care not to cross-thread the connection. Do not use tools.
NOTE: The regulator threads are left handed. The
regulator will seal in the cylinder valve resulting in some
resistance. An additional one-half to three-quarters
turn is required to complete the connection. If you
cannot complete the connection, disconnect and repeat
the above two steps. If you still cannot complete the
connection, DO NOT use this regulator!
 Inspect valve connection port and regulator. Look for any
damage or debris. Remove any debris. Inspect hose for
damage. Never attempt to use damaged or plugged
equipment. See your local propane dealer for repairs.
To disconnect:
 Hold regulator firmly and turn coupling nut clockwise to
remove.
 Place cap on cylinder valve outlet whenever the cylinder
is not in use.
NOTE: Only install on the cylinder valve outlet the type of
cap that is provided with the cylinder valve. Other types
of caps or plugs may result in leakage of propane.
TESTING VALVES, HOSE, AND REGULATOR
FOR LEAKS
DANGER:
DO NOT smoke or use an open flame during leak
test. If a leak is present, the gas could ignite and
result in serious personal injury.
WARNING:
To avoid serious personal injury, always check for
gas leaks any time the propane cylinder is discon-
nected and then reconnected.
Connections on the hose and regulator were tested at the
factory to ensure no gas leaks were present. However, ship-
ping and handling could loosen connections. As a safety
precaution:
 Turn the propane heater OFF ( O ).
 Make sure the regulator is properly connected to the
propane cylinder.
 Turn handwheel counterclockwise to open the cylinder
valve.
NOTE: If you hear a rushing sound, immediately turn off
the cylinder valve. This sound means there is a major leak
at the connection. Correct the problem before proceeding.
 Using a clean paint brush and a 50/50 mixture of mild
soap and water, brush soapy solution over all the con-
nections and fittings on the product and at the propane
cylinder.
 "Growing" bubbles indicate a leak. Close the cylinder
valve then retighten all connections.
NOTE: If leaks cannot be stopped, do not try to repair.
Call for replacement parts.
 If you are not using the propane heater immediately after
the leak test, close the cylinder valve by turning the valve
clockwise.
8 - English