Step 4
Figure 7
shows the wall-mount bracket for the power supply and the mounting-screw holes
on the back of the bracket. Align the mounting-screw holes with a wall stud, or use wall
anchors.
Figure 7
Wall-Mount Bracket for Power Supply
a. For attaching to a wall stud, use two #10 wood screws (round- or pan-head) with #10
washers, or two #10 washer-head screws. The screws must be long enough to penetrate at
least 3/4 inch (20 mm) into supporting wood or into a metal wall stud.
b. For hollow-wall mounting, wall must be at least 1/2 inch (12.7 mm) thick. Use two wall
anchors with washers. Wall anchors and washers must be a size suitable for the wall to which
they are mounted.
Step 5
Position the power supply in the bracket.
a. Orient the front and back of the power supply vertically.
b. Position the end nearest the power cable at the top.

Rack-Mount the Cisco Unified 500 Series

Note
The Cisco Unified 500 Series and power supply can be installed in 19-inch racks only, and can
only be front mounted.
Attach Brackets for Rack-Mounting
To attach the brackets to the Cisco Unified 500 Series, perform the following steps.
Caution
Do not overtorque the screws. The recommended torque is 6 to 8 in-lb (0.7 to 0.9 N-m).