Regulation For Lpg - Smeg AS28I96L Instructions For Installation And Use Manual

Smeg range instructions for installation and use
Table of Contents

Advertisement

3.2 Regulation for LPG

Loosen screw A and push air
regulator B to the bottom.
With a 7 mm wrench, remove nozzle
C and replace it with the proper one
(follow
reference tables for the type of gas
to be used).
The torque wrench setting of the
nozzle must not exceed 3 Nm.
Regulate the air by sliding regulator
B until reaching distance "X" shown
in the table in paragraph "3.4
Regulation of primary air".
Lock
screw A.
Burner
Top with front controls:
Auxiliary
Semi rapid
Rapid
Ultrarapid
Top with side controls:
Auxiliary
Semi rapid
Rapid
Ultrarapid
26
Instructions for the installer
the
instructions
regulator
B
by
Rated
heating
capacity
(kW)
Nozzle
diameter
1/100 mm
1.05
1.65
2.55
3.25
1.05
1.65
2.55
3.25
on
the
tightening
LPG – G30/G31 28/37 mbar
By-pass
mm
1/100
48
33
62
33
75
50
85
68
48
33
62
33
75
45
85
65
Reduced
Flowrate
flowrate
g/h G30
(W)
420
76
420
120
900
185
1500
236
450
76
450
120
800
185
1500
236
Flowrate
g/h G31
75
118
182
232
75
118
182
232