5.3 Regulation for natural gas

The hob has been inspected for G20 (2H) natural gas at a pressure of
20 mbar. To allow the unit to work with this type of gas, perform the same
operations described in paragraph "5.2 Regulation for LPG", but choose
the nozzles and regulate the primary air for natural gas, as shown in the
following table and in paragraph "5.4 Regulation of primary air". After the
regulations have been carried out, restore the seals with sealing wax or
equivalent material.
Burner
Auxiliary (1)
Triple crown (2)
Double crown
internal (3)
external (3)
5.4 Regulation of primary air
Referred to distance "X" in mm.
BURNER
Auxiliary (1)
Triple crown (2)
Double crown
Instructions for the installer
Rated heating
capacity
(kW)
1.05
3.3
0.8
3.3
internal (3)
external (3)
Natural gas – G20 20 mbar
Nozzle diameter
1/100 mm
73
130
115
250
G20
20 mbar
1.5
1.5
8.5
1
Reduced flowrate
(W)
380
1200
380
1200
G30/G31
28/37 mbar
2
3
9
9
27

Advertisement