Page 1
IDS701-CTRUCK Weighing Indicator User manual...
Page 2
IDS701-CTRUCK User Manual safety instruction For safety operation pls. follow the safety instruction. WARNING set. Calibrate, inspect and fix the the weighing indicator is prohibited by Non professional staff WARNING Pls. make sure the weighing display well earthing WARNING The indicator is electrostatic sensitive device, pls.
IDS701-CTRUCK User Manual 2. Installation and Calibration 2.1 connection indicator with loadcell IDS701-CTRUCK can connect four pcs 350Ωload cell at most, both four and six wire load cell are ok. To make it simple, we use quick disconnect Or standard plug. As belows...
Page 6
IDS701-CTRUCK User Manual RS232 communication interface connection RS232 communication interface for printer use DB9 definition RS232 communication interface connection Pin function and definition as bellows: DB9 joint Definition Function Sending data Receiving data Ground interface Page 5 of 21...
IDS701-CTRUCK User Manual 3. Basic operation 3.1 Key and display IDS701-CTRUCK Weighing indicator display instruction LED display instruction Weighing data display Page 6 of 21...
Page 8
IDS701-CTRUCK User Manual Weight unit kg Tare Display tare weight Display net weight Gross Display gross weight Display data keep still zero, indicating zero weight Over setting weight Within setting weight Below setting weight 。 Decimal point Page 7 of 21...
IDS701-CTRUCK User Manual Key’s function Key symbol Key name Key function ZERO Clear weight within zero range ZERO PRINT Print current weight PRINT RE-PRINT Print last weight RE-PRINT ON/OFF Press it for 2 seconds to power on or power off ON/OFF 3.2 Power on...
IDS701-CTRUCK User Manual 4. Calibration and parameter setting 4.1 Enter setting There have two methods to enter the setting menu: 1. when the “span” is not pressed down, Press RE-PRINT still and then press ON/OFF enter C08-C39 setting. 2. Take out the sealing screw on the back of indicator, then press down the “span”...
Page 11
IDS701-CTRUCK User Manual step display Remark Method of operation [C01 After you enter to calibration mode, it display [C01 press Weight unit option:1=kg 2=lb press [C02 Set decimal digits press [C02 option:0/1/2/3/4 [C02 Select decimal digit press example:two decimal point:...
Page 12
IDS701-CTRUCK User Manual press [C06 option: 0=Non-load calibration [C06 1= load calibration press Basic on max capacity setting, press [SPAN add suitable weight on scale. [0100.00] close to the max capacity, heavier than 10% max at least. [0080.00] For example: the weight is 80kg...
Page 13
IDS701-CTRUCK User Manual 4.3 Application function parameters setting chart Setting Function parameters setting and instruction Item Options: 0 = close warning tone warning warning 1 = open warning tone tone tone option:0=close auto power off 10= keep still within 10 min. power off...
Page 14
IDS701-CTRUCK User Manual Lower limit alarm value Inner Code At setting function mode, after display Check inner code directly enter C15,indicator will show inner code Enter C16, you can direct to set Date the current date, from left to right:...
Page 15
IDS701-CTRUCK User Manual 5=± 5% max capacity 10=± 10% max capacity 20=± 20% max capacity option:0.0= close automatic zero tracking 0.5=± 0.5d 1.0=± 1.0d 2.0=± 2.0d Automatic 3.0=± 3.0d Automatic zero zero tracking 4.0=± 4.0d tracking range 5.0=± 5.0d remark:1.d is the set graduation 2、...
Page 16
IDS701-CTRUCK User Manual 2= slow option:1=1d 2=2d 5=5d Standstill range 10=10d Note: d=division Digital filter option:0= close dynamic filter Dynamic filter 1=1 digital filter strength : Instruction 2=2 digital filter strength Dynamic filter is 3=3 digital filter strength collecting the data...
IDS701-CTRUCK User Manual 5.Output data format 5.1 Big display continuous sending format Output continuous format State A Bits0,1,2 Decimal point position XXXXXX0 XXXXXXX XXXXX.X XXXX.XX XXX.XXX Bits3,4 Division State B BitsS function Bits0 gross=0, net=1 Bits1 symbol:positive =0,negative =1 Bits2 overload(or lower zero)=1...
Page 18
IDS701-CTRUCK User Manual Bits4 unit:lb=0, kg=1 Bits5 Constant 1 Bits6 Constant 0 State C Bit2 Bit1 Bit0 unit Kg or lb Bit 3 printing=1 Extend Bit 4 display=1 Bit 5 Constant 1 Bit 6 Constant 0 5.2 Print output format Date: 12.09.01...
IDS701-CTRUCK User Manual 6. Maintenance 6.1 Regular Error and maintain method Error Reason instruction Solution 1. the loaded weight 1.decrease loaded weight excess overload 2. check load cell range of max. capacity connection 3. checking load cell : Display 2. wrong connection...
Page 20
IDS701-CTRUCK User Manual during calibration, the Added weight at least added weights 10%of Max. capacity, ERR2 enough Recommend the weights 60-80% Max. capacity during calibration, 1..Check connection is input single correct or not. negative. 1. Check load cell is ERR3 damaged or not.
Page 21
IDS701-CTRUCK User Manual setting. Note:Pls. do not restore default parameter easily if you are not professional and have not scale calibration. Default parameter form parameter instruction Default value Calibration unit decimal digits Division value Max capacity 10000 Empty scales calibration...
Page 22
IDS701-CTRUCK User Manual Automatic zero tracking range Automatic zero tracking time Verload range Negative display range Standstill time Standstill range Dynamic filter Noisy filter C30~C40 Reseverd menu Page 21 of 21...