Installation Instructions for the
HDLS Series Switches
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency
stop devices or in any other application where failure
of the product could result in personal injury.
Failure to comply with these instructions could
result in death or serious injury.
MOUNTING
All Heavy Duty Limit Switches (HDLS) have exactly the
same mounting dimensions. Mount by either of two
methods: (a) use two #10 screws from the front, or (b)
use two #10-32 UNF screws from the back. HDLS offers
the advantage of front mount construction. The
electrician will find a complete switch, with no parts
missing and ample wiring space.
With plug-in construction, wiring and conduit connection
is made to the base receptacle. This feature also
reduces downtime, since plug-in unit can be removed
without disconnecting wiring or conduit.
To mount either switch, merely tighten mounting screws,
tighten plug-in unit or cover screws, and make sure
conduit section is sealed. Use of sealant (teflon tape,
pipe dope, etc.) is recommended to seal conduit
connection.
Because of moisture condensation problems, it is not
good practice to mount the switch upside down or at the
low point of conduit runs.
Single-Pole – Plug-in Type
Sensing and Control
Double-Pole – Non
Plug-in Type
Sealing
IP67/68
Enclosure Type
1, 3, 3R, 4, 4X, 6, 6P, 12, 13
Rated Operational Voltages (Ue) and Currents (Ie)
Ue
120 Vac
600 Vac
125 Vdc
250 Vdc
WIRING
Use size #12AWG or smaller solid or
stranded wire to connect to the
pressure type connector terminals.
Spades may be up to .312" wide,
rings up to .312" dia. With spade or
ring type connections, preinsulated
connectors or heat-shrinkable tubing
should be used to provide insulation
between terminals. Circuit diagram is
shown on the nameplate.
It will be easier to wire the double-
pole units by connecting lead wires to
the terminals nearest the conduit opening first. A
grounding screw is located in the housing near the
conduit opening.
Switch units with an indicator light in the cover are
furnished with the lead wires from the light connected to
the normally-open male terminals (#3 and #4) unless
otherwise specified on the order. Wires can be
unsoldered and reconnected to the normally-closed male
terminals or they can be ordered connected to the
normally-closed terminals by using a modification code
(refer to Catalog 40). Always connect these wires to the
same set of terminals used for the load. Across the
normally open male terminals (#3 and #4) the light will
be On (Fig. 1). Across the normally closed terminals (#1
and #2) the light will be Off.
ISSUE 2
PK 81116
Ie
6 A
1.2 A
0.22 A
0.11 A

Advertisement

loading

Summary of Contents for Honeywell HDLS Series

  • Page 1 ISSUE 2 Installation Instructions for the PK 81116 HDLS Series Switches WARNING Sealing IP67/68 PERSONAL INJURY Enclosure Type 1, 3, 3R, 4, 4X, 6, 6P, 12, 13 DO NOT USE these products as safety or emergency stop devices or in any other application where failure Rated Operational Voltages (Ue) and Currents (Ie) of the product could result in personal injury.
  • Page 2: Changing Direction Of Actuation

    2. On the bottom of the head, insert a screwdriver in slot provided (Fig. 2) and lift open hinged cover. 3. Referring to Fig. 3, slide cam all the way back, so cam is free to rotate on the shaft. 2 Honeywell • Sensing and Control...
  • Page 3: Replacement Parts

    LSZ7R1A LSZ4001 LSZ1R LSZ3J LSH2B LSZ7R2B LSZ4002 LSZ1R LSZ3B LSU1A LSZ7U1A LSZ4001 LSZ1U LSZ3A LSV1A LSZ7V1A LSZ4001 LSZ1V LSZ3J LSV1J LSZ7V1J LSZ4001 LSZ1V LSZ3A LSV5A LSZ7V5A LSZ4001 LSZ1V LSZ3A LSV8A LSZ7V8A LSZ4001 LSZ1V LSZ3A Honeywell • Sensing and Control 3...
  • Page 4 +44 (0) 1698 481481 While we provide application assistance personally, through our literature and the +44 (0) 1698 481676 Fax Honeywell web site, it is up to the customer to determine the suitability of the product in the Latin America +1-305-805-8188 application.
  • Page 5 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Honeywell LSZ1AC LSZ7YAC1A LSZ7YAB1A...

This manual is also suitable for:

Pk 81116