Honeywell 5800SS1 Installation Manual

Wireless shock sensor
Hide thumbs Also See for 5800SS1:

Advertisement

Quick Links

FCC / IC STATEMENTS ARE IN THE MIDDLE OF PAGE 2
5800SS1 Wireless Shock Sensor
5800SS1
5800SS1
5800SS1
Wireless Shock Sensor
Wireless Shock Sensor - - - - Installation Guide
Wireless Shock Sensor
GENERAL INFORMATION
The 5800SS1 is a wireless shock sensor
intended for use in systems that support 5800
series devices. Each transmitter has its own
unique
serial
number,
assigned
manufacture, which must be "enrolled" in the
control panel before the device can be used
with the system. Refer to the control panel's
Installation and Setup Guide for programming
details.
One 5800SS1 is required for each pane of
glass protected. (Do not use more than one
sensor per pane.)
Types of Glass Protection
Tempered
Ordinary Plate
Laminated Type
Wired
*
Coated
Sealed Insulated
*
Not for use in UL installations.
Note: It is not necessary to remove the case
cover during installation.
ENROLLING THE 5800SS1
You must enroll the 5800SS1 serial number
in
the
control
panel
during
programming. The control panel's Installation
and
Setup
Guide
provides
programming
procedures.
programming, perform the following:
1.
To cause the transmitter to transmit,
remove the "PULL TO CONNECT
BATTERY" tab (see Figure 1). (For
additional transmissions, lightly tap on
the
base
of
the
sensor
screwdriver.)
SENSOR
TAB
PULL TO CONNECT BATTERY
K5867
PULL
Figure 1
2.
When programming the shock
sensor, note the following:
Input Type = 3 (Supervised RF)
Loop Number = 1
during
3.
When prompted for the serial number,
you can transmit by lightly tapping on
the base of the sensor with a
screwdriver or by manually entering
the serial and loop number.
MOUNTING
1.
Determine
the
location. For best sensitivity, the
sensor should be mounted one-inch
from the corner edge of the window
frame (see Figure 2).
STRIKE AT
FURTHEST
OPPOSITE
CORNER WITH
SCREWDRIVER
HANDLE
Figure 2
zone
2.
Before the transmitter is permanently
mounted, conduct Go/No Go tests (see
detailed
control's instructions) to verify adequate
Before
signal
strength
location.
3.
Always verify range by holding the
sensor in the approximate mounting
location and tapping at the base. The
panel (in test mode) should respond to
the transmissions. If not, find a more
with
a
suitable mounting location.
4.
Clean the glass, where the sensor will be
mounted, with a mixture of water and
isopropyl alcohol.
5.
Once the glass has dried, remove the
tape backing paper and firmly press the
sensor in the desired mounting location.
6.
Verify operation by striking the furthest
opposite corner of the glass with the
handle of a large screwdriver. Always
check the alarm panel keypad to verify
that the zone has tripped.
5800SS1-001-V0
7.
Apply optional "WARNING" label to the
outside glass surface opposite the tape
side of the 5800SS1.
optimum
mounting
10 FT. RADIUS
MAXIMUM
COVERAGE
1in.
1in.
MOUNT 1 INCH FROM CORNER
OF WINDOW FRAME.
from
the
mounting

Advertisement

loading

Summary of Contents for Honeywell 5800SS1

  • Page 1 Installation and Setup Guide for programming the serial and loop number. details. MOUNTING One 5800SS1 is required for each pane of Determine optimum mounting glass protected. (Do not use more than one location. For best sensitivity, the sensor per pane.)
  • Page 2 FOR WARRANTY INFORMATION AND DETAILS REGARDING THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM REFER TO THE INSTALLATION INSTRUCTIONS FOR THE RECEIVER/CONTROL USED WITH THIS DEVICE. 2 Corporate Center Drive, Suite 100 ÊK0011V1†Š P.O. Box 9040, Melville, NY 11747 Copyright  2011 Honeywell International Inc. K0011V1 1/12 Rev. A http://www.honeywell.com/security...