Modular Aluminum Compressed Air Piping Installation Instructions
PLANNING/LAYOUT
Before beginning the installation, create a plan as to the location of the air compressor and where you are
going to mount the compressed air outlets. On the plan locate outlets, tees, and elbows.

AIR COMPRESSOR

Use a flexible jumper hose from the air compressor to the filter regulator unit to reduce vibration to the
FastPipe System.
FILTER REGULATOR
A filter regulator unit is reccomended to keep
contaminants out of the air system and to allow for
pressure adjustment.
PRESSURE RATINGS
The FastPipe system has a maximum working pressure
of 190 psi and a temperature range from 0 to 140 deg F.
ASSEMBLY OF THREADED COMPONENTS
Assemble all NPT threads with two wraps of teflon tape
and then PIPE SEALANT which prevents thread galling.
FLAT SURFACE INSTALLATION
• Hangers or mounting clips should be no more than
10 ft apart and one must be at least 6" from a fitting
Pipe Clip
• Use pipe clips to secure pipe to any flat surface with
mounting screw
• Ceiling or wall mount
• Clip has 5/16" thru hole and hex bore for a 5/16" hex nut
• Hex nut serves at a backer for screws
• Use #10 Drywall Screw or Tapcon
• In horizontal installations, mount clip pivot tab up
IF YOU ARE EXPERIENCING TROUBLE WITH THIS PRODUCT, OR
MISSING PARTS, PLEASE CALL 800-954-3310 FOR ASSISTANCE
Strut Cushion Clamp
DO NOT RETURN TO STORE
HANGING INSTALLATION
• Beam Clamp
• 5/16" Threaded Rod
• Pipe Clip
EXPANSION JOINTS
Any piping system will expand and contract with temperature changes, use this
guide for installation of expansion joints to compensate for this movement of
aluminum pipe in non-conditioned buildings
3/4"-2"
• Beam Clamp
• 3/8" Threaded Rod
• Pipe Clip
MAXIMUM STRAIGHT RUN DISTANCE
TEMP
3/4"
1"
11/2"
CHANGE
10°F
700ft
550ft
600ft
500ft
20°F
500ft
420ft
460ft
370ft
35°F
350ft
280ft
310ft
250ft
55°F
260ft
200ft
230ft
190ft
70°F
200ft
170ft
190ft
150ft
2"

Advertisement

loading

Summary of Contents for RapidAir FastPipe

  • Page 1: Air Compressor

    PRESSURE RATINGS The FastPipe system has a maximum working pressure of 190 psi and a temperature range from 0 to 140 deg F. ASSEMBLY OF THREADED COMPONENTS Assemble all NPT threads with two wraps of teflon tape and then PIPE SEALANT which prevents thread galling.
  • Page 2 Outlet ports are 1/2” Female NPT, Drain port is 3/8” Female NPT Use a pipe thread bushing 1/2” Male NPT x 1/4” Female NPT to adapt standard 1/4” quick couplers Or use a Rapidair K7241 1/2” Male NPT Quick Coupler #50716...
  • Page 3 FASTPIPE INSTALLATION TIPS AND RECOMMENDATIONS: Care must be taken on any installation of the Fastpipe system. Pipes will be carrying compressed air/gas up to 190 psi. The Fastpipe system is only as safe as a thorough installation. Read all installation instructions and watch installation videos before starting. Below are some tips for a safe installation.