Samsung Version 1.1 Owner's Manual
Samsung Version 1.1 Owner's Manual

Samsung Version 1.1 Owner's Manual

Samsung web transmitter owner's manual

Advertisement

WEB
W EB
TRANSMITTER
SNS-110 Owner's Manual
(Version 1.1)
4
1 2

Advertisement

Table of Contents
loading

Summary of Contents for Samsung Version 1.1

  • Page 1 W EB TRANSMITTER SNS-110 Owner's Manual (Version 1.1)
  • Page 2 Before You Begin This manual is the basic guide for all Web Transmitter SNS-110 users. It mainly illustrates product background, installation method, and connection through web browsers as well as GUI (Graphic User Interface) after connection. Please, familiarize yourself of the contents in this manual before using SNS-110 product. Make sure you refer to an expert when opening the outer case for the purpose of repair.
  • Page 3 Regulation Approval Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interface in a residential installation.
  • Page 4: Table Of Contents

    Table of Contents Chapter 1. SNS-110 Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 Functions and Feature - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 Names and Function - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8...
  • Page 5 Chapter 7. Administration Mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 42 Initial Screen - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 42 Camera Set-up - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 43 PAN/TILT/ZOOM Set-up - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 45...
  • Page 6: Chapter 1 Sns-110 Overview

    Chapter 1 SNS-110 Overview Overview SNS-110, connected to surveillance cameras or other external devices, compresses video image as motion JPEG through zip algorithm and transmits it to a remote party through network (Ethernet, cable modem). SNS-110 may be connected to maximum of 4 video images and concurrently transmits the image in a form of single screen, quadruplex screen, or automatic sequential screen.
  • Page 7 You can send video image files through FTP server at certain time or in regular intervals. Users can access the FTP server and search the saved video files. You can change the LOGO image on SNS-110 screen, or background color or font colors. Search SNS-110 to download the latest software at http://www.samsungelectronics.com/...
  • Page 8: Names And Function

    Names and Function Familiarize yourself with the names and function of each part on the front and back panels, before installing SNS-110. Front View of SNS-110 Name Receives input from maximum of 4 video image signals. Video In Transmit the image output to cameras or other external video-imaging devices Video Out When connected, the terminal resistance of 75Ω...
  • Page 9 Rear of SNS-110 R/O RX TX ALARM IN RA RC Name Sensor Input : 1,2,3,4 Alarm Input(1,2,3,4) Signal GND : G R/O (Relay Out) RX(+,-) RS-485(+,-) TX(+,-) RS-232C 9Pin DSub Connector Network Port RJ-45 Connector Power In RS-232C - + - + Connects to maximum of 4 alarm sensors.
  • Page 10: Chapter 2 Installing Sns-110

    Chapter 2 Installing SNS-110 Preparation and installation of SNS-110 Setting Configuration Please, familiarize yourself of the safe condition of SNS-110 installation. This product must be horizontally stabilized and not be sloped or vertically positioned. Positioning and properly centering its wiring room are crucial for its aptitude function. If the devices are too near with each other, or if the ventilation is not sufficient, it may trigger the system malfunction and make its maintenance as well as repair difficult to achieve.
  • Page 11: Cautions In Installation

    Cautions in Installation Be aware of the following cautions when installing SNS-110. Always turn the power off before SNS-110 installation. Severe impact or vibration may cause malfunction. Avoid places with strong magnetic or electric field, or places near a radio or TV. Always keep the place dust-free when installing or moving SNS-110.
  • Page 12 15Cm Position it in an open space with flat surface, keeping the aptitude temperature. Also, maintain the clearance between back of the main body and the wall. Be careful not to insert accidentally any conducting material in the ventilation space of product. Turn the power off and disengage the power cord from the body, when changing the circuit-protecting fuse.
  • Page 13 Do not neglect fumes or unusual odor, which may be symptoms of malfunction. When these are identified, please instantly disconnect the power and consult to an expert from your local service center. NOTE Always use a dry cloth when cleaning this product. If the contamination is serious, please wipe it first with a neutral detergent, then with a dry cloth.
  • Page 14: Unpacking

    Unpacking When you purchase SNS-110, after removing the wrap, place the product on a flat surface or where you will be installing it. Then, check if there is any missing part among the following items. SNS-110 Main Body User’s Guide Power Adapter (1EA) Power Cord (1EA) RS-232C Cable (1EA)
  • Page 15: Chapter 3. Connecting To Instruments

    Chapter 3. Connecting to Instruments You may connect the following items with SNS-110, such as video image players (e.g., VTR, DVDP, etc.,), network devices, alarm sensors, PAN/TILT/ZOOM/FOCUS controllers, and PC-connected consoles. Caution No voltage, more than DC 2V, must be connected to the video in/output terminal 1~4.
  • Page 16: Connecting To External Instruments

    Connecting to External Instruments VTR, DVDP, TV CAMERA VIDEO IN SNS-110 produces the video image signal of the corresponding channel, if connected with external instruments to Video Out 1~4 (loop through BNC). The terminal resistance of 75Ω will be automatically seized by the connection with external instruments.
  • Page 17: Connecting To Network

    Connecting to Network Ethernet(10BaseT/100BaseT) ALARM IN INTERNET Cable Modem ALARM IN R/O RX TX 1 2 0 3 4 0 RA RC INTERNET ETHERNET RS-232C R/O RX TX RA RC - + - + Back Bone ETHERNET RS-232C - + - + Cable Modem Back Bone CMTS...
  • Page 18: Connecting To Alarm Sensors And External Devices

    Connecting to Alarm Sensors and External Devices ALARM IN R/O RX TX RA RC - + - + Function Name Alarm In Alarm 1/2/3/4/G Relay Out RA/RC Alarm sensors and external devices are usable by connecting to ALARM IN and R/O terminals of the reverse side of the SNS-110 respectively.
  • Page 19: Connecting To Pan/Tilt/Zoom/Focus Camera Controller

    The PAN/TILT/ZOOM/FOCUS controllers that are supported are the following. Samsung Smart-Dome Camera (SCC-641) Sungjin Electronic Communications : CPU-Receiver When connecting Samsung Smart-Dome Camera (SCC-641), you have to connect the Note SNS-110 to the TxDt, - terminals of SCC-641. In this case, the supportable Baud Rate is 38400 and 19200bps.
  • Page 20: Connecting To Rs-232C

    Connecting to RS-232C When connecting PC serial port (COM1, COM2) through RS-232C from back of SNS-110, you may select console mode of SNS-110 by using PC terminal emulation program (HyperTerminal). Control S/W from the front panel must be positioned "OFF". Caution In the console mode, if you change the existing data improperly, the system may result in serious problems.
  • Page 21: Creating Rs-232C Cable

    Creating RS-232C Cable The RS-232C Cable is packed with SNS-110, and so you don’t need to make it . The wiring diagram shown below is for your information. 9Pin Female to 25Pin Female 9Pin Female to 9Pin Female Terminal Emulation Communication Set-up Items Baud Rate Data Bit...
  • Page 22: Creating Ethernet Cable

    Creating Ethernet Cable Since the Ethernet Cable is not packed with SNS-110, the user has to purchase and use it . Connected from SNS-110 to Hub (Direct Cable) RJ - 45 ALARM IN Web Browser Connected from SNS-110 to PC(Twisted Cable) RJ - 45 ALARM IN R/O RX TX...
  • Page 23: Chapter 4 Setting An Ip Address

    Chapter 4 Setting an IP Address No information upon network is set up except Ethernet address (MAC address) in factory defaults. You must set up the IP address when installing. Caution Ethernet address (00-00-f0-XX-XX-XX) is recorded on the bottom of the product at the time of purchase.
  • Page 24: Setting In Ethernet

    Setting In Ethernet (10BaseT/100BaseT) For Windows 95/98/ME/NT/2000/XP (1) Open Dos window from network-connected PC with SNS-110. (2) Execute "arp -s". arp -s <SNS-110 IP Address> <SNS-110 Ethernet Address> Example : arp -s 168.219.15.250 00-00-f0-ff-a1-0a (3) Confirm if the IP address completely agrees with Ethernet address as shown below by executing "arp -a". arp -a Example : arp -a...
  • Page 25 (4) Wait until you receive the normal response after executing "ping". ping <SNS-110 IP Address> - Example : ping 168.219.15.250 - 110 -n 20 Pinging 168.219.15.250 with 32 bytes of data: Request timed out. Request timed out. No Response Request timed out. Request timed out.
  • Page 26: Setting In Unix

    Setting in Unix (1) Execute the following instruction for network-connected Unix machines with SNS-110. (2) Execute "rarp -s". rarp -s <SNS-110 IP Address> <SNS-110 Ethernet Address> Example : rarp -s 168.219.15.250 00:00:f0:ff:a1:0a (3) Confirm if the IP address completely agrees with Ethernet address as shown below by executing "rarp - a". rarp -a Example : rarp -a...
  • Page 27 (4) See if you receive the normal response as shown below after executing "ping". ping <SNS-110 IP Address> Example : ping 168.219.15.250 PING 168.219.15.250 (168.219.15.250): 56 data bytes 64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms 64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms 64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms 64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms 64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms...
  • Page 28: Setting With Ip Installer

    Setting with IP Installer The 'IP Installer' is an application program that supports easy setting of network parameters of SNS-110 such as IP Address, Gateway, Subnet Mask and so on. Before executing the 'IP Installer', the SNS-110 should be connected with PC through RS-232C cable. The 'IP Installer' works on Windows 95/98/ME/NT/2000/XP. Program Name of IP Installer : SetupWebTX_v11.exe Note You can download the 'SetupWebTX_v11.exe' at 'http://www.samsungelectronics.com'.
  • Page 29 Note If the serial port which you select is being used by other device, you will see the following window. In this case, you have to stop the usage of serial port by other device or change the connection of SNS-110 to other serial port. (4) If the SNS-110 and PC is successfully connected through RS-232C cable, you will see the following window.
  • Page 30 (6) Set up or modify the network parameters, and then click the 'OK' button. (7) If the setting of network parameters succeeds, you will see the following window.
  • Page 31 (8) After the setting of network parameters, the SNS-110 will automatically reboots. If all of the network parameters are properly set, you can connect SNS-110 with Web Browser. Note If the 'success' message window does not appear even though you wait more than 10 seconds after clicking 'OK' button, stop the program by clinking 'Cancel' button.
  • Page 32: Setting Other Network Information

    Password : w2000 (3) After logged in, set up the additional network information in administration mode. (4) Be sure to reset or switch off and then switch on your SNS-110 after setting. Note Please, refer to Chapter 5 and 7 for Log-in and administration mode network setting up.
  • Page 33: In Cable Network Through Cable Modem

    In Cable Network through Cable Modem (1) Connect according to "Connecting to Cable Modem" of Chapter 3 Connecting to Network, and turn the SNS-110 power on. (2) SNS-110 automatically receives the following information from the cable network manager by executing DHCP (Dynamic Host Configuration Protocol), if connected to cable network through a cable modem.
  • Page 34: Chapter 5 Sns-110 Log-In

    Chapter 5 SNS-110 Log-in After successfully setting up an IP address as in Chapter 4, execute a web browser (Netscape or Explorer) from an Internet PC. Ideal Specification If your PC performance is not compatible, the image processing speed will decrease in your web browser, resulting in possible short-image.
  • Page 35: Log In Through Explorer

    (3) If you have properly logged in, you will see the following. (4) Properly enter user name and password and click "OK" button. You should see the initial screen of Chapter 6 Application Mode. Log-in through Explorer First Time (1) If you have never logged in through Explorer, first download plug-in program from SNS-110. Then, follow the next procedure.
  • Page 36 (4) Enter the SNS-110 IP Address in Address : xxx.xxx.xxx.xxx (5) If you have properly logged in, you will see the following. (6) Properly enter user name and password and click "OK" icon. Then, you should see the security message.
  • Page 37 (7) Click "Yes". You just have completed downloading Explorer plug-in program from SNS-110. Then, you will see the initial screen of Chapter 6, Application Mode. (8) If security level is set to "High",then the following window appears and the program cannot be installed.
  • Page 38 Others (1) The initial user name and password in factory defaults are as follows. User Name : root Password : w2000 (2) Log-in window appears only under the following condition. When "Password Enable" is set in the Web Transmitter setting of the Administration mode and you have access to the Application mode, Log-in window appears.
  • Page 39: Chapter 6. Application Mode (Video Image Monitoring Mode)

    Chapter 6. Application Mode (Video Image Monitoring Mode) Initial Screen (1) If you have entered correct user name and password or clicked "Application" button, you will see the next initial screen of application mode. (2) You will see the quadruplex screen with 4-video image input. And, without any image input, you will see "No Video"...
  • Page 40: Quadruplex Screen

    Quadruplex Screen (1) Click "Quad" button on left side of the screen. You will see 4 individual screens in the quadruplex screen. (2) Click any of the 4 screens to view it in single screen. Automatic Sequential Screen (1) Click "Sequential" button on left side of the screen in Application mode. You will see 4 screen sequentially altering.
  • Page 41: Single Screen With Pan/Tilt/Zoom Controllers

    Single Screen with PAN/TILT/ZOOM Controller (1) After enabling PAN/TILT/ZOOM in Administration mode, if you select an image from "Camera 1~4" button, you will see the next screen. (2) Before operating PAN/TILT/ZOOM, the PAN/TILT/ZOOM controllers must have been connected, and P/T/Z configuration must have been established in Administration mode. (3) You will see scrolling bars around the image.
  • Page 42: Chapter 7 Administration Mode

    Chapter 7 Administration Mode Initial Screen (1) You must enter "root" for the user name and its password in the Log-in window to transfer to the below Administration mode screen for both password-enable and password-disable condition. (2) If the camera does not operate normally after accessing to the Administration mode, the camera icon that is located on the screen blurs.
  • Page 43: Camera Set-Up

    Camera Set-up (1) You will see the following screen by clicking "Camera" icon in Administration mode. (2) Camera Input Automatically recognizes image broadcasting system (NTSC/PAL), Color/Black &white, or No Video. If you click "Refresh" button at any time, this function will run through and set up new configuration of image broadcasting system (NTSC/PAL), Color/Black &white, or No Video.
  • Page 44 (6) PAN/TILT/ZOOM Select "Disable", if Pan/Tilt/Zoom controller is not connected. At this time "Preset" button is inactivated. If Pan/Tilt/Zoom are properly connected, select "Enable". (7) Preset It will activate "Preset" button. At this time, you will see the next screen, and you may remotely control the position of camera.
  • Page 45: Pan/Tilt/Zoom Set-Up

    +, - terminals of RS-485 on the rear of your web transmitter. For further information, refer to Chapter 3. "Connecting to PAN/TILT/ZOOM/FOCUS Camera & Controller". Here are the supported PAN/TILT/ZOOM/FOCUS camera & controller. Smart Dome Camera & Controller, made by Samsung Electronics P Protocol Dome Camera and Receiver, made by PELCO CPU Receiver, made by Sungjin Electronics...
  • Page 46: Quad/Sequential Set-Up

    Quad/Sequential Set-up (1) You will see the next screen by clicking Quad/Sequential icon in Administration mode. (2) Quad Size Select from either Small or Normal. (3) Sequential Size Select one from Small/Normal/Large. (4) Sequential Interval You may select the sequential interval from 3secs to 60secs. Your selected time will be the interval between 4 input images in the sequential screen.
  • Page 47: Web Transmitter Set-Up

    Web Transmitter Set-up (1) You will see the next configuration window by clicking "Web Transmitter" in Administration mode. (2) Date & Time Select date and time. (3) Security New root pswd Changes root password. New password must be more than 3 letters and less than 32, and must include Arabian numbers.
  • Page 48 (4) S/W Upgrade Upgrade the currently installed program in SNS-110 to the most updated version. Download the updated program version from Samsung Electronics web site . (www.samsungelectronics.com), or from SNS-110 service man. The file name of SNS-110 program is sns110_vXXX_XXXX.bin.
  • Page 49 Caution Be careful not to install any other file except SNS-110 program (sns110_vXXX_XXXX.bin) during S/W upgrade. You might accidentally trigger the fatal system damage. Always reboot, after the system is upgraded. After upgrading, Network setting (IP Address, DNS ) is not changed but the user s input is initialized after rebooting and it has to be specified at Administration Mode.
  • Page 50: Alarm/Relay Set-Up

    Setting the ALARM / RELAY Out (1) Connect the alarm sensor to another device according to the ‘Chapter 3 Connecting to Instruments’. The alarm level of the alarm terminal 1~4 is the following. Normal condition : TTL High Level (DC 5V) Alarm : TTL Low Level (DC 0V) (2) If the alarm is set off the SNS-110 sends video images connected to alarm terminal 1~4, by E-mail or to the FTP server on a set time gap.
  • Page 51 (6) Enable Each alarm terminal has to be set as for whether the "Mail" or "FTP" transfer function is going to be used. If the alarm sensor isn't installed or if the input signal can be ignored, click "No". (7) Pre-alarm If the video image transfer is set to FTP and the alarm went off, this will send the images that were sent before the alarm.
  • Page 52: Network Set-Up

    Network Set-up (1) You will see the next configuration window by clicking "Network" in Administration mode. (2) IP Address Enter SNS-110 IP Address. If the IP Address has been properly set up according to Chapter 4 Setting up IP Address, the IP Address will automatically be set up and shown in the window. If the IP Address is changed in use, re-set the IP Address on this menu.
  • Page 53 (8) Gateway Set up the Gateway Address assigned by the network manager. (9) DHCP (Dynamic Host Configuration Protocol) DHCP is protocol, which automatically assigns IP address in network environment. Those network environments automatically assigned with IP Address are as follows. Set DHCP "Yes"...
  • Page 54 (11) FTP Server Specifies the FTP Server address to send still image. The server address has to be either network IP Address where SNS-110 can access or Host Name. (12) FTP Port Set the FTP Port to transfer still images to the FPT server. Default setting is at 21. (13) User Specifies the User ID to access FTP server.
  • Page 55: File Transter Set-Up

    File Transfer Setting (1) Click "File Server" at Administration Mode to open the following window and to specify the file transfer through the FTP server. (2) Camera 1~4 Specifies the FTP transfer for input image from Camera 1 to Camera 4. Click "No" not to use FTP transfer, click "Once"...
  • Page 56 (5) Between Specifies the starting and finishing time of image file transfer. It only applies to files which were set as "Every" or "Both" at (2). You can set "Time"(0~23), "Minute"(0~59), or "Second"(0~59). If starting and finishing time are identical, image files are transferred all day.
  • Page 57: Custom User Interface Setup

    Custom User Interface Setup (1) By clicking the "Web Browser" icon in the Administration Mode, the Custom User Interface setting window appears. Start page, page title, background color, font color and language can be set up, as the user wants. (2) Start Page The start page in the Application Mode allows a choice between one of Camera 1~4, Quad, and Sequential.
  • Page 58: About/Support/Help

    ABOUT/ SUPPORT/ HELP (1)ABOUT Provides you information on SNS-110. (2)SUPPORT Samsung Electronics’ English Version Homepage(http://www.samsungelectronics.com/)is linked. Search for an webTX or SNS-110, and you can download SNS-110 user manual, a last update program and troubleshooting instructions.
  • Page 59 (3 )HELP Provides you with help messages on each function. You can see help message as shown below by clicking in the configuration window of Administration mode. Ex) the Help that appears when the is clicked on the Camera setting window.
  • Page 60 APPENDIX SNS-110 SPECIFICATIONS...
  • Page 61: Appendix A

    APPENDIX A SNS-110 SPECIFICATIONS SPECIFICATIONS Video In/Out Composite 4 Channel, Color & Black/White NTSC/PAL compatible BNC Type Loop Through Out 1.0 Vp-p, 75 Hi Z Termination type Hardware 32Bit RISC CPU 2MByte Flash Memory 32MByte SDRAM Operation System RTOS (Real Time OS) Network Interface 10BaseT Ethernet 100BaseT Fast Ethernet...
  • Page 62: Serial Connector

    Performance Max 30 Frame/Sec (1 User Single Mode Connection) Alarm In Input 4 Port TTL Level "Low" Active Sends the Video screen through E-mail/FTP in case when alarm sets off Pre-Alarm Relay Out Output 1Port Regular Capacity of Relay - 2A 30VDC - 0.5A 125VAC Serial Connector RS-232C 1 Port (9 Pin D-Sub): Console...
  • Page 63 Regulation Approval Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interface in a residential installation.
  • Page 64: Appendix

    APPENDIX Factory Default...
  • Page 65: Appendix B

    APPENDIX B Factory Default Factory Default sets the program back to the condition at the time of purchase. Please note that after Factory Default has been enabled, network information is also deleted, so establishing a connection is impossible. Refer to Chapter 4, Setting an IP Address, in order to set a new IP address. How to Enter the Factory Default (1) Power on the SNS-110 or push the ‘Reset’...
  • Page 66 Therefore, you must be extremely careful when you execute this function. Factory Default Value Blank Blank Blank Blank Camera 1,2,3,4 Mail : 1/ FTP: 10 None 0.0.0.0 0.0.0.0 Blank 0.0.0.0 Blank 0.0.0.0 0.0.0.0 Blank Blank Blank 0:0:0 1frames/1Minute 0:0:0 and 0:0:0 Everyday Quad Web Transmitter-Samsung Electronics/(No) #b8b8b8/(No) Black/(No) logo.gif/(No) English...
  • Page 67 APPENDIX How to Use Console...
  • Page 68: Appendix C

    Message (1) When the power is turned on, the following message will appear on the console screen when SNS-110 has been successfully installed. ######################################################## SAMSUNG Electronics. Co., Ltd. webTX(Internet Video Server):SNS-110 Version1.1(2000~2001) All Rights Reserved. ######################################################## >Current status is Flash Memory Boot >To change system parameter, press any key within 2 seconds...
  • Page 69 PTZ control task started. >Log In : (2) When you correctly enter user name "root" and password, the following message will appear. >Log In : root >Password : >Welcome to SAMSUNG webTX SNS-110 SNS-110> Indicates the software version loaded on SNS-110...
  • Page 70 Command (1) help: Indicates Command items SNS-110> help telnet ping help status tftpdn reset freset jpgtest SNS-110> (2) ping: Indicates the connection status to a given IP Address SNS-110> ping 168.219.13.115 ping (168.219.13.115): 56 data bytes 168.219.13.115 is alive SNS-110> (3) status: Indicates the current condition and information of SNS-110 SNS-110>...
  • Page 71 1 min, betw 00:00:00~00:00:00, day 1 --Dynamic IP reg enabled, server:<> cgi:</cgi-bin/webtx.cgi?regist=%e&host=%i> mail enabled, addr:<webtx@samsung.co.kr> --User Interface title disabled, <WebTransmitter - Samsung electronics> bgcolor disabled, <#b8b8b8> txtcolor disabled, <black> logo disabled, <logo.gif> ********** DHCP network parameters ********** system boot with fixed IP saved in NVRam ---- SNS-110>...
  • Page 72 SNS-110> reset reset after 0 second. SNS-110> Reset requested!!! reset after 1 ms >Application shutdown ############################################################### SAMSUNG Electronics. Co., Ltd. webTX(Internet Video Server):SNS-110 Version1.1(2000~2001) All Rights Reserved. ############################################################### >Current status is Flash Memory Boot >To change system parameter, press any key within 2 seconds ...
  • Page 73 (1) Once you turn the power on and SNS-110 functions normally, the following message will appear, and if you press any key, you will be able to set the values manually. ######################################################## SAMSUNG Electronics. Co., Ltd. webTX(Internet Video Server):SNS-110 Version1.1(2000~2001) All Rights Reserved.
  • Page 74 Space Bar or Enter, the following screen appears. (2) When the following message appears by running the above item, you can manually set the information relating to Network. -------------------------------------------- [WEB Transmitter(SNS-110) Version 1.1] Boot command Loop menu -------------------------------------------- [p] Print Boot Parameters...
  • Page 75 (4) If you enter "c" when "Select items?" appears, you will be provided with the menu, which will allow you to manually set the network information. Select items? [ ] c [ WEB Transmitter ( SNS-110 ) Version 1.1 ] Boot parameters modification menu -------------------------------------------- [i].
  • Page 76 (5) If there is information you would like to change or update, you can do so at this time. Select items? [ ] i LAN IP address? [0.0.0.0] 168.219.13.113 168.219.13.113 Turning off DHCP mode... Warning To use the Static IP Address, put "0" for DHCP flag and to use the Dynamic IP Address, put "1."...
  • Page 77: Appendix

    APPENDIX Dynamic IP Information Transfer...
  • Page 78: Dynamic Ip Information Transfer

    [p] Print Boot Parameters [c] Change Boot Parameters [q] Quit Menu ------------------------------------------- Select items? [ ] c [ WEB Transmitter ( SNS-110 ) Version 1.1 ] Boot parameters modification menu -------------------------------------------- [i]. Ip address modify [s]. Subnet mask address modify [m].
  • Page 79 Enter "5" and go to IP notify-mail address to type E-mail address you want. Select items? [ ] 5 IP notify-mail address? [webtx@email.com] user@samsung.co.kr Enter "4" and go to IP notify-mail enable/disable and enable it. Select items? [ ] 4 IP notify-mail enable? [Y] Select Quit menu to exit Boot Command Mode.
  • Page 80 [p] Print Boot Parameters [c] Change Boot Parameters [q] Quit Menu ------------------------------------------- Select items? [ ] c [ WEB Transmitter ( SNS-110 ) Version 1.1 ] Boot parameters modification menu -------------------------------------------- [i]. Ip address modify [s]. Subnet mask address modify [m].
  • Page 81 Type "1" and go to IP auto-regist server address" to type registered Web Server address. The example below is the IP Address such as 168.219.44,137 or registered host name such as www.samsung.co.kr. [ WEB Transmitter ( SNS-110 ) Version 1.1 ] Boot parameters modification menu -------------------------------------------- [i].
  • Page 82 Electronics only provides methods for Ethernet Address and IP aAddress, which transmit to the Administration server. Administration Server have to save and manage the information (Ethernet Address and IP Address) which it received. Users must deploy saving and managing program for this and Samsung Electronics can provide help for that.
  • Page 83 Setting with the Web Browser When you have SNS-110 address and can access through the Web Browser, you can change the setting as above at the Administrator Mode. When you run the Network Setting window as explained in the Chapter 7 and click "Advanced"...
  • Page 84: Faq

    APPENDIX...
  • Page 85 (4) Check the values assigned for Domain Name, SMTP server setting at Administration mode. Ex) Domain Name: samsung.co.kr SMTP Server : vcr.sec.samsung.co.kr or 168.219.13.12 (5) Make sure the E-mail address entered on the 'sender' of the Alarm/Relay Out in the Administration Mode is valid.
  • Page 86 (2) If LED of Network for SNS-110 is working correctly, the values for Network within SNS-110 might have been incorrectly entered. In such a case, refer to Supplement B Factory Default to turn the settings to the factory mode. Then, retry setting the IP address again, as shown in Chapter 4. The PC to setup the IP Address at SNS-110 must use the IP Address that has the same network as the IP Address to setup at SNS-110.
  • Page 87 When SNS-110 does not work after downloading to upgrade to the latest version of the S/W of SNS-110 (1) If you upgraded SNS-110 by using a separate file other than one was supplied by Samsung Electronics, it becomes non-functional. (2) If your SNS-110 doesn't function at all, even though the software normally supplied by Samsung...
  • Page 88 If the Video image has problems when connected to SNS-110 using a Netscape (1) This can happen if Netscape 6.0 or above is used. (2) Use Netscape 5.X or below. (3) The defects related to Netscape 6.0 are being fixed. You cannot use FTP for transfer when setting up FTP transfer (1) Check [Start] –...
  • Page 89 E E L L E E C C T T R R O O N N I I C C S S AB68-00278A...