FITTING THE PROGRAMMER
If surface wiring has been used, remove the knockout/insert from the
bottom of the programmer to accommodate it.
Loosen the two 'captive' retaining screws on the bottom of the
Backplate. Now fit the programmer to the Backplate, ensure the lugs
on the Backplate engage with the slots on the programmer .
Swing the bottom of the programmer into position ensuring that the
connection pins on the back of the unit locate into the terminal slots
in the backplate.
Tighten the two 'captive' retaining screws to fix the unit securely.
Then switch on the mains supply.
UPON COMPLETION OF INSTALLATION PLEASE RESET THE PROGRAMMER.- DETAILED BELOW
RESETTING THE PROGRAMMER
On the CentaurPlus press SET and SELECT buttons together:
Then release the buttons and the programmer will return
to preset factory settings.
The preset factory settings are illustrated on page 2 of the
USER GUIDE.
The unit can now be programmed to suit the User's requirements.
Please refer to the User's Guide provided.
GENERAL INFORMATION
Before handing over the installation to the user, always ensure that the system responds correctly on
all control programmes and that other electrically operated
equipment and controls are correctly adjusted.
EXPLAIN HOW TO OPERATE THE CONTROLS AND HAND OVER THE USERS OPERATING INSTRUCTIONS TO THE
SPECIFICATION C11 - C17
Contact type: Micro dis-connection (Voltage Free)
Contact rating: 3(1)Amps 230-240V AC
Power supply: 230-240V AC 50Hz
0 o C to 40 o C
Operating Temperature range:
Double insulated.
Dirt protection: Normal situations.
Enclosure protection: IP30
Purpose of control: Electronic time switch
Independently mounted control for surface mounting.
Operating time limitation: Continuous
Type 1 Action
Battery Reserve: 10 months continuous operation(minimum)
Case material: Thermoplastic, flame retardant
Horstmann Controls Limited
Email: sales@horstmann.co.uk
Website: www.horstmann.co.uk
t:0117 9788 773 - f:0117 9788 701
PAGE 4
END VIEW OF CENTAURPLUS PROGRAMMER
SET
USER.
Dimensions: 150mm x 84mm x 29mm
Display: Liquid crystal
Clock: 12 hour AM/PM
Display time adjustment: 1 Minute steps
Switched time adjustment: 10 Minute steps
Programme selection: Auto, On all day, On constant, Off, Holiday
Operating periods per day: Three
(Separate daily programmes for C17)
Override:
1 Hour Boost
Instant advance
Backplate: Industry Standard Backplate
Bristol
BS4 1UP
LEAFLET No P60490
Horstmann's CentaurPlus - Single Channel Programmers
to three programmed operating periods per day with Boost and
Advance control.
INSTALLATION AND CONNECTION SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON
AND IN ACCORDANCE WITH THE CURRENT EDITION OF THE IEE WIRING REGULATIONS.
WARNING : ISOLATE MAINS SUPPLY BEFORE COMMENCING INSTALLATION
SELECT
Once
the
Backplate
removed from the packaging please
ensure the programmer is re-sealed
to prevent damage from dust, debris
etc.
The Backplate should be fitted with
the wiring terminals located at the
top and in a position which allows a
total clearance of at least 50mm
around the programmer.
DIRECT WALL MOUNTING
Offer the plate to the wall in the position where the programmer is to be mounted, remembering that
the Backplate fits to the left hand end of the programmer. Mark the fixing positions through the slots
in the Backplate(Fixing centres 60.3mm), drill and plug the wall, then secure the plate in position. The
slots in the Backplate will compensate for any misalignment of the fixings.
WIRING BOX MOUNTING
The Backplate may be fitted directly on to a single gang steel flush wiring box complying with BS4662,
using two M3.5 screws. CentaurPlus programmers are suitable for mounting on a flat surface only, they
must not be positioned on a surface mounted wall box or on unearthed metal surfaces.
All necessary electrical connections should now be made. Flush wiring can enter from the rear through
the aperture in the Backplate. Surface wiring can only enter from beneath the programmer and must
be securely clamped.
The mains supply terminals are intended to be connected to the supply by means of fixed wiring.
The recommended cable sizes are 1.0mm 2 or 1.5mm 2 .
ISSUE 4
FITTING THE BACKPLATE
has
been
ELECTRICAL CONNECTIONS
Offer up
PAGE 1

Advertisement

loading

Summary of Contents for Horstmann C11

  • Page 1 Backplate engage with the slots on the programmer . Swing the bottom of the programmer into position ensuring that the connection pins on the back of the unit locate into the terminal slots Horstmann’s CentaurPlus - Single Channel Programmers Offer up in the backplate.
  • Page 2 Other control components shown in the diagrams i.e. Valves, RoomStats etc are general representations only. However the wiring detail can be applied to the corresponding models of most manufactures e.g. Horstmann, Honeywell, Danfoss Randall, ACL Drayton etc. Cylinder and Room Thermostat Key:...