3-4. List of memory switches

NOTE:
In standard memory switch setting mode (refer to the CD instruction manual), the bottom two digits only display memory
switch Nos. 00 to 49.
To make the bottom two digits display memory switch Nos. 50 to 99, switch the sewing machine to Administrator memory
switch setting mode. (Refer to the previous page.)
Work clamp setting (001 to 099)
No.
Work clamp height when treadle is depressed.
001
Settings can be made in units of 1 mm.
Work clamp height when treadle is at neutral position.
002
Settings can be made in units of 1 mm.
Work clamp operation when treadle is depressed to the 1st step.
* When using a triple pedal (optional part), this number will not be
displayed.
003
1: Work clamp does not drop to intermediate position.
2: Work clamp drops to intermediate position.
Work clamp height (mm) when dropped to intermediate position.
* Displayed when No. 003 above is set to "2".
004
Settings can be made in units of 0.1 mm.
Sewing machine starting procedure (pedal type).
050
1: Treadle.
*1
3: Triple pedal.
Pausing enabled during automatic sewing when treadle is depressed backward.
* When using a triple pedal (optional part), this number will not be
displayed.
052
OFF: Pausing is not allowed.
ON: Pausing is allowed.
Work clamp operation when using a triple pedal.
* When using a treadle, this number will not be displayed. (Refer to P. 15.)
* Neutral indicates that the work clamp is at the neutral position.
1: Remains lowered even when the work clamp switch is released, intermediate
lowering disabled, and starting prohibited when at neutral.
2: Remains lowered even when the work clamp switch is released, intermediate
lowering enabled, and starting prohibited when at neutral.
3: Remains lowered even when the work clamp switch is released, intermediate
lowering disabled, and starting allowed when at neutral.
053
4: Remains lowered even when the work clamp switch is released, intermediate
lowering enabled, and starting allowed when at neutral.
5: Returns to neutral when the work clamp switch is released, intermediate
lowering disabled, and starting prohibited when at neutral.
6: Returns to neutral when the work clamp switch is released, intermediate
lowering enabled, and starting prohibited when at neutral.
7: Returns to neutral when the work clamp switch is released, intermediate
lowering disabled, and starting allowed when at neutral.
8: Returns to neutral when the work clamp switch is released, intermediate
lowering enabled, and starting allowed when at neutral.
*1 This is not initialized during initialization mode. Also not overwritten from SD card.
Setting items
HE-800B
3. FUNCTION SETTINGS
Setting range
Default value
1 to 13
13
1 to 13
10
1 to 2
1
0.1 to 8.0
1.0
1,3
1
ON/OFF
OFF
1 to 8
1
8

Hide quick links: