Brother AiRScouter WD-360B Quick Setup Manual

Hide thumbs Also See for AiRScouter WD-360B:

Advertisement

Quick Links

Printed in Japan
D00VM8001
WD-360B
Quick Setup Guide
Before using the AiRScouter, make sure you read the Product Safety
Guide first. Then read this Quick Setup Guide for correct setup and use
of the AiRScouter, and keep it for future reference.
Note that product options and accessories may vary depending on the
country of sale.
 Product Safety Guide (included in the box)
This guide provides important safety information for the AiRScouter.
Read it carefully before use.
 Quick Setup Guide (this guide)
This guide provides basic information about setting up and using the
AiRScouter, as well as detailed tips for troubleshooting problems that
may occur.
 User's Guide (available online at Brother Solutions Center)
This guide provides additional information on settings,
operation, troubleshooting, and maintenance. Visit
the Brother Solutions Center at support.brother.com,
select Manuals, and search for your product.
Unpack the machine and check
the components
Before using the AiRScouter, make sure that you have all the
components shown below.
Head Display Unit
Li-ion (Lithium Ion)
Rechargeable Battery
Flexible Arm
Quick Setup Guide
(For Right Eye)
*1 The cable clip may be used to attach the head display cable to your
clothing to keep it out of your way. Loop the string of the cable clip around
the head display cable as shown.
*2 The case is used for storage only. If the product falls or receives a strong
impact while in the case, it may become damaged.
English
Control Box
AC Adapter
*1
Cable Clip
Rear Band
Product Safety Guide
(This Guide)
*2
Case
Belt Pouch
Names and functions of key components
Head Display
a
a Focus Adjustment Dial
Adjusts the focus of the image on the head display by changing
the focal length of the optics (from 30 cm to infinity).
b Head Display Cable
Connects the head display to the control box and transmits power
and video signals to the head display.
c Eyecup
When attached, prevents the head display from touching the
user's eye.
Harness
b
c
f
e
a Head Band
Attaches the AiRScouter to the user's head and distributes the
weight of the unit.
b Forehead Pad
Cushions the head band and prevents it from slipping down the
user's forehead.
c Cable Channel
Holds the head display cable in place along the head band.
d Rear Band Attachment Post
Allows the user to attach the rear band and tighten the head band
around the head to prevent slippage.
e Flexible Arm
Allows the user to adjust the position and angle of the head display
relative to the eye.
f Joint Dial
Loosens the ball joint to allow for adjustment of the flexible arm,
or tightens it to fix the flexible arm's position and angle.
c
b
a
d

Advertisement

Table of Contents
loading

Summary of Contents for Brother AiRScouter WD-360B

  • Page 1 This guide provides basic information about setting up and using the AiRScouter, as well as detailed tips for troubleshooting problems that may occur.  User's Guide (available online at Brother Solutions Center) This guide provides additional information on settings, operation, troubleshooting, and maintenance. Visit the Brother Solutions Center at support.brother.com,...
  • Page 2: Control Box

     LED Indications Control Box flashing a Display LED (Green) State Name Explanation The AiRScouter is receiving Display ON a compatible video signal from an external device. The control box is processing the (Slowly) Operating video signal. a Control Panel The AiRScouter is not receiving (Quickly) No input...
  • Page 3: Before Using The Airscouter

    Before using the AiRScouter How to assemble the AiRScouter Note • If an input source with an unsupported resolution is connected, the Ensure the AiRScouter is powered and connected correctly according to image may not display correctly on the head display screen. If this the following procedure: occurs, check the output resolution of the video source.
  • Page 4: Adjusting The Settings

    Enlarge or reduce the size of the image Note Press the mode button • If the ball joints become loose after adjusting the position of the head to enlarge or reduce display, turn the dials on either end of the flexible arm clockwise to fix the head display in place.
  • Page 5: Attach The Rear Band

    Attach the rear band Rotate the dial on the ball joint between the flexible arm and the head band clockwise, until the flexible arm is separated from the head band. Press the area highlighted in the image below, and slide the head band cover towards the end of the band to remove it.
  • Page 6: Power Supply

    Power supply Attach the flexible arm to the head band by lining up the wide end of the flexible arm with the threads on the head band, and rotating the dial on the ball joint clockwise to tighten. Important • The AiRScouter can use the following power supplies: - The AC adapter supplied in the box - The internal battery supplied for use inside the control box...
  • Page 7: Troubleshooting

    If, after reading the troubleshooting tips, you are unable to resolve your battery. problem, visit the Brother Solutions Center at support.brother.com The internal Connect the AC adapter to the battery AiRScouter to charge.
  • Page 8: Requesting Repairs

    In particular, usage at a high charge rate (90% or more) in a hot place greatly For FAQs, troubleshooting and more, visit the Brother Solutions Center accelerates the deterioration of the Li-ion rechargeable battery.