en | Network Default Setting
10
Network Default Setting
In case of forgetting network setting of BioEntry Plus (TCP/IP or
RS-485 setting) during installation or using BioEntry Plus, user
can initialize network setting (TCP/IP or RS-485 setting) by
using DIP SW installed on the back panel of BioEntry Plus.
Please refer to the figures in below.
How to initialize Network Setting
1.
2.
3.
4.
5.
6.
NOTICE!
Please set the IP address of a PC to 192.168.0.x (except 1) to
meet IP bandwidth of the device.
| V 1.1 | 2010.10
Turn off BioEntry Plus power.
Please make DIP SW #2 ON (Please refer to figure1.)
After turning on BioEntry Plus power, user can modify
TCP/IP or RS-485 setting what user wants.
Network default settings:
–
TCP/IP address: 192.168.0.1
–
Not checked Use server
–
RS485: PC connection, 115200bps
Please modify TCP/IP or RS-485 setting and save it.
Please make DIP SW #2 OFF (Please refer to figure 2.)
After recycling BioEntry Plus power, please check the
modified TCP/IP or RS-485 setting.
Installation manual
BioEntry Plus
Bosch Access Systems GmbH